Installing CAP Ms
Cat6A Cable Requirements for Ethernet Devices
If you connect an Ethernet device to a Fiber CAP M, you must observe the following rules.
Plenum rated cable must be used whenever it is required by local electrical codes.
Shielded twisted pair is not required unless operating in a high RFI/EMI environment.
CommScope strongly recommends using factory terminated and tested Cat6A Patch Cord.
24 AWG Cat6A cabling is sufficient for the cable run between the Fiber CAP M and the Ethernet device.
The maximum attached cable length at Port A is 3 meters (9.8 feet).
Prepare for Installation
Do the following before beginning installation.
Review and know the cautions in "Safely Working with Era Hardware” on page 10.
Review the system design plan.
Identify the equipment installation site, which must be able to support the weight of the CAP M, see
"Determine the Mounting Site” on page 20.
Review the power requirements to make sure the site can support this installation.
Map out all cable runs.
Identify and obtain all tools and materials required to complete the installation; see "Recommended Tools
and Material” on page 18
Recommended Tools and Material
The following tools and material is required for installation are not supplied by CommScope.
Electrostatic Discharge (ESD) wrist strap
Drill and bits that can penetrate the selected mounting surface
SW10 wrench
Single Mount
Single Mounting Bracket (CommScope PN 7821955-xx)
Four M6 screw anchors rated for the mounting surface
Dual Mount
Dual Mounting Bracket (CommScope PN 7821954-xx)
Four M6 screw anchors rated for the mounting surface
For installations using the optional Hybrid Fiber Splice Box
Hybrid Fiber Splice Box (CommScope PN 7693816-xx)
Torx T20H screwdriver
Earth-bonding cable to ground the CAP M chassis
Fiber cleaning equipment.