User guide
Andrew, A CommScope Company  
3 Westbrook Corporate Center, Suite 900, Westchester, Illinois U.S.A. 60154   
U.S.A.: +1 (800) 279-8185 • International: +1 (703) 726-5556 
WWW.CommScope.Com
© 2008 CommScope 
639568 • Revision C •  November 2008
Page 3 of 6
Figure 2. Configuring Site Information into the PWR-COBRA Interface for a RET Antenna. 
13. To store data in the Operator Data fields, use the information gathered during installation 
and also enter the Installation Date, Installer’s Identification (this can be the company or 
the individual name), Base Station ID, Sector, Bearing, and the amount of mechanical 
downtilt set on the antenna during the installation. Once this information is entered, click 
on SET to save this information to the flash memory at the antenna. Repeat this step for 
each antenna located on the tower until all parameters are complete. 
14. To set the electrical downtilt for each antenna actuator, first double click on the first 
antenna serial number shown in the Vendor/Serial Number box on the Identification 
screen. Enter the password (the password should be entered using lower case letters), 
and then click on Connect and Enable. The Response window should display 
CONNECTED. Select the Settings tab then the AISG tab. Enter the desired downtilt in 
the Tilt Setting box at the top, then click the Set button. Repeat this step until all 
antennas at the site have the desired electrical downtilt setting. See Figure 2. 