User`s manual

Page 9Fiberlink® 3370 Series User’s Manual
Fiberlink® 3370 Series
Installation Instructions (cont.)
6) Connect the ber optic cable(s) to the transmitter and receiver units.
Note: when using two ber version, you must connect the transmitters Optical A to
the receivers Optical A and the transmitters Optical B to the receivers Optical B.
7) Connect the Universal Power Supply to the transmitter and receiver units.
For box versions using DC power, please refer to gure 1.
8) Congure your data preferences as described in the Data Conguration
section of this manual.
9) When power is applied, the green POWER LED should illuminate, indicating the
presence of operating power. The 3G/HD/SD RATE LEDs and the data LEDs will
give an indication as described in the Indicator LED’s and Alarm Circuitry section
of this manual.
10) The system should now be operational.
Note: The Rack Card version has an additional red LED for indicating the presence of an alarm
condition (loss of signal). Refer to Indicator LED’s and Alarm Circuitry sections of this manual.
Installation Instructions
The transmitting element in the Fiberlink® 3370 transmitter
unit contains a solid state Laser Diode located in the optical
connector. This device emits invisible infrared electromag-
netic radiation which can be harmful to human eyes. The
radiation from this optical connector, if viewed at close
range with no ber optic cable connected to the optical
connector, may be sucient intensity to cause
instantaneous damage to the retina of the eye. Direct
viewing of this radiation should be avoided at all times!
Figure 1:
Power Connector
DC Input Polarity
9-24 Volts
AC or DC
(+) Positive
( - ) Negative