Ship Power Bus Terminal
Ship Power into the Distribution Unit must connect to the Power Bus block. The Distribution
Unit protects the Vector and Display Head power from Ship Power over voltage and reverse
voltage faults. It is important that the Vector and Display Heads receive their power input
from the protected power connections on their connector block.
Ship
Power
and
Polarity
Indicator
Figure 10 - Ship Power Connection
In figure 10, the top tier of terminals, on the Power Bus block, are electrically connected
together on the Distribution Unit and be connected to the positive (B+) Ship Power wire.
The bottom tier of terminals, on the Power Bus block, are electrically connected together on
the Distribution Unit and be connected to the negative (B-) Ship Power wire
The indicator LED will be GREEN if:
Ship Power is applied, AND
polarity (B+, B-) are correct.
If an over voltage or reverse voltage condition occurs on the Ship Power terminal, a
thermally-resetting fuse will break. Once the Ship Power fault condition is corrected, it may
take several minutes for the thermal fuse to reset.
Post Check
Before applying ship power, check the following:
All wires are secure
No frayed wire strands come out of the terminal blocks
Cord grips are tight
Power Up Test
To power up the Distribution Unit and verify that it is functioning:
Turn on Ship Power (B+ and B-).
Verify GREEN Power