Installation Manual

INS_CLFE4+2SMS[POE](C,U)_REV– 10/27/11 PAGE 4
INSTALLATION AND OPERATION MANUAL CLFE4+2SMS[POE](C,U) SERIES
TECH SUPPORT: 1.888.678.9427
Installation Instructions
1 - SET DATA RATE DIP SWITCHES
Locate the 10/100 data rate DIP switch on the unit.
Set the data rate according to bandwidth required.
NOTE: The data rate must be set the same on both the local and remote units.
2 - SET WIRE PAIR DIP SWITCHES (UTP MODELS ONLY, FOR COAX MODELS SKIP TO STEP 3)
Locate the wire pair DIP switch on the unit.
Set the pair according to number of twisted wire pairs used (1 or 4).
NOTE: The number of pairs selected must be set the same on both the local and remote units.
Figure 2 – One-Pair Pin Assignment
For 1-pair mode, use the first pair of pins (pins 1 and 2) of the
“Extended Ethernet” RJ-45 port.
3 - SET LOCAL/REMOTE DIP SWITCHES
Set the Local/Remote switch to Local (LC) for Local (head end) devices or Remote (RM) for Remote (field end) devices.
4 - SET CL1 UP LINK ENABLED DIP SWITCH
Set the Up Link switch to the “ON” position to enable Uplink port features.
5 - CONNECT EXTENDED WIRING
Connect Extended Distance Port to field wiring.
6 - CONNECT NETWORK WIRING
Using Cat5/5e, connect Local unit to network and Remote unit to camera.
7 - CONNECT POWER
Connect power to unit per the following table.
NOTE: Remove Electrical Connector for Rack Mount Units
Table 2 – Power Connections per Use Case
Non-PoE PoE Models Only
Operating Voltage 12 to 24 VDC (9 VDC
when in C1 or C2 Rack)
48 to 56 VDC
Use Power Connectors RTN and +Vin RTN and +Vin
Contact the ComNet Design Center, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.
8 - VERIFY FUNCTIONALITY
See LED table below and Troubleshooting Guide if corrective action is needed.
Table 3 – Indicating LEDs
PWR Link (Ethernet Port) Activity (Ethernet Port) L/A (CH 1 or 2) POE (PoE Models Only)
SOLID Power Applied Link Detected Link Detected Supplying PoE to PD(s)
BLINKING Data Activity Data Activity
OFF Power Off No Link No Link Not Supplying PoE to PD(s)