INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ ENVIRONMENTALLY HARDENED MANAGED ETHERNET SWITCH WITH (8) 10/100TX + (2) 10/100/1000TX RJ45 OR 100/1000 FX SFP PORTS v2.0 December 2012 The ComNet™ CNGE2FE8MSPOE+ Managed Ethernet Switch provides transmission of eight (8) 10/100BASE-T(X) and two (2) 10/100/1000T(X) or 100/1000FX combo ports.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Contents Regulatory Compliance Statement 6 Warranty 6 Disclaimer 6 Safety Information 6 Overview 7 Introduction 7 Software Features 8 Hardware Features 9 Safety Indications 9 Hardware Installation Installing Switch on DIN-Rail 10 10 Mount Series on DIN-Rail 11 Wall Mounting Installation 12 Mounting the CNGE2FE8MSPOE+ on a Wall Hardware Overview 12 13 Front Panel 13 Front Panel LEDs 15 Top view Panel 16 Rear Panel 17 Cable
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ System Information 24 System Information 24 Enable Location Alert 24 Basic setting 25 Switch Setting 25 Admin & Password 25 IP Setting 26 Time Setting 27 PTP Client 29 LLDP 29 Auto Provision 30 Backup & Restore 31 Upgrade Firmware 31 Redundancy 32 C-Ring 32 Legacy Ring 34 COM-Ring 35 C-RSTP 36 RSTP 37 RSTP setting 37 MSTP 40 Multicast 44 Static Multicast Filtering Port Setting 45 46 Port Control 46 Port Stat
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Qos policy 53 Port-base priority 54 COS/802.1p 55 TOS/DSCP 56 DHCP Server 57 DHCP Server – Setting 57 DHCP Server – Client List 58 DHCP Server – Port and IP bindings 58 DHCP Server –DHCP Relay Agent 59 SNMP 60 SNMP – Agent Setting 60 SNMPV3 61 SNMP –Trap Setting 62 Security 63 Management Security 63 Static MAC Forwarding 64 MAC Blacklist 65 802.1x 66 802.1x - Radius Server 66 802.1x-Port Authorized Mode 68 802.
INSTALLATION AND OPERATION MANUAL Command Line Interface Management About CLI Management CLI Management by Telnet. CNGE2FE8MSPOE+ 81 81 84 Commands Level 85 Symbol of Command Level.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Regulatory Compliance Statement Product(s) associated with this publication complies/comply with all applicable regulations. Please refer to the Technical Specifications section for more details. Warranty ComNet warrants that all ComNet products are free from defects in material and workmanship for a specified warranty period from the invoice date for the life of the installation.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Overview Introduction The CNGE2FE8MSPOE+ is a powerful managed industrial Ethernet switch containing many unique features. These switches can work under a wide temperature range, dusty environment and humid condition. CNGE2FE8MSPOE+ supports PoE or Power over Ethernet, a system to transmit electrical power with data to remote devices over standard twisted-pair cable.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Software Features »» World’s fastest Redundant Ethernet Ring: C-Ring (Recovery time <10ms over 250 units connection) »» Supports Ring Coupling, Dual Homing over C-Ring »» Supports SNMPv1/v2/v3 & RMON & Port base/802.1Q VLAN Network Management »» Event notification by Email, SNMP trap and Relay Output »» Web-based, Telnet, Console, CLI configuration »» Enable/disable ports, MAC based port security »» Port based network access control (802.1x) »» VLAN (802.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Hardware Features »» Two Redundant DC power inputs (48–57VDC) »» Wide Operating Temperature Range: -40 to +75ºC »» Storage Temperature Range: -40 to +85ºC »» Operating Humidity: 5% to 95%, non-condensing »» Casing: Aluminum »» 10/100BASE-T(X) Ethernet port »» 10/100/1000BASE-T(X) Gigabit Ethernet port (combo) »» 100/1000BASE-X on SFP port (combo) »» Console Port »» Dimensions (W × D × H): 74.3mm × 109.2mm × 153.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Hardware Installation Installing Switch on DIN-Rail Metal Spring Each switch has a Din-Rail kit on the rear panel. The DIN-Rail kit affixes the switch to the DIN-Rail. It is easy to install the switch on the Din-Rail: INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Mount Series on DIN-Rail Step 1: Tilt the switch and mount the metal spring to DIN-Rail. Step 2: Push the switch toward the DIN-Rail until you hear the spring snap into place . INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Wall Mounting Installation Each switch has another installation method for users to install the switch. A wall mount kit can be found in the package. The following steps show how to mount the switch on the wall: Mounting the CNGE2FE8MSPOE+ on a Wall Step 1: Remove Din-Rail kit if it is attached to the switch. Step 2: Use the 6 included screws to attach the wall mount panel as shown in the diagram below.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Hardware Overview Front Panel The following table describes the labels on the CNGE2FE8MSPOE+. Port Description 10/100 RJ-45 fast Ethernet ports 8 10/100BASE-T(X) RJ-45 fast Ethernet ports support auto-negotiation.
CNGE2FE8MSPOE+ 10/100/1000 TX INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ PWR PWR1 1000FX G2 G2 G1 LNK/ACT 3 Ring Fault G1 4 5 6 7 10/100/1000 TX 13 2 R.M. 1000FX 14 1 PWR2 Console 8 Reset P7 P8 P5 P6 12 11 P3 P4 10 P1 P2 10/100/1000 TX P.O.E. 7 8 5 6 3 4 1 2 9 www.comnet.net 1 (203) 796-5300 CNGE2FE8MSPOE+ 1. LED for PWR. When the PWR links, the green LED will be light on. 2. LED for PWR1. When the PWR1 links, the green LED will be light on. 3. LED for PWR2.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Front Panel LEDs LED Color Status Description PWR Green On DC power ready PW1 Green On DC power module 1 activated. PW2 Green On DC power module 2 activated. R.M Green On C-Ring Master. Ring Green On C-Ring enabled. Slowly blinking C-Ring topology has fault Fast blinking C-Ring works normally. On Fault relay. Power failure or Port down/fail.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Top view Panel The bottom panel components of CNGE2FE8MSPOE+ are shown as below: 1. Terminal block 2. Ground wire INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Rear Panel The components in the rear of CNGE2FE8MSPOE+ are shown as below: 1. Screw holes for wall mount kit. 2. DIN-Rail kit 1 2 1 INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Cables Ethernet Cables The CNGE2FE8MSPOE+ switch has standard Ethernet ports. According to the link type, the switches use CAT 3, 4, 5, 5e UTP cables to connect to any other network device (PCs, servers, switches, routers, or hubs). Please refer to the following table for cable specifications. Cable Type Max.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Pin Number Assignment 1 BI_DA+ 2 BI_DA- 3 BI_DB+ 4 BI_DC+ 5 BI_DC- 6 BI_DB- 7 BI_DD+ 8 BI_DD- 1000 BASE-T RJ-45 Pin Assignments The CNGE2FE8MSPOE+ switch will support auto MDI/MDI-X operation. You can use a straightthrough cable to connect a PC to the switch. The table below shows the 10BASE-T/ 100BASE-TX MDI and MDI-X port pin outs.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ The switch has fiber optic ports with SFP connectors. The fiber optical ports are available with multi-mode and single-mode fiber with various distance and connector types. Please remember that the TX port of Switch A should be connected to the RX port of Switch B. Switch-A Switch-B Console Port Cable CNGE2FE8MSPOE+ switches can be managed by the console port. The DB-9 to RJ-45 cable can be found in the package.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ 5 1 9 DB9 Male 6 1 5 6 9 DB9 Female Pin Male Connector Female Connector 1 Received Line Signal Detect (Received by DTE Device) Received Line Signal Detect (Transmitted from DCE Device) 2 Received Data (Received by DTE Device) Transmitted Data (Transmitted from DCE Device) 3 Transmitted Data (Transmitted from DTE Device) Received Data (Received by DCE Device) 4 DTE Ready (Transmitted from DTE Device) DTE Ready (Received by DCE Device)
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ WEB Management Attention: W hile installing and upgrading firmware, please remove physical loop connection first. DO NOT power off equipment while the firmware is upgrading! Configuration by Web Browser This section details configuration through the Web browser. About Web-based Management An embedded HTML web site resides in the flash memory on the CPU board.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Preparing for Web Management The default value is as below: IP Address: 192.168.10.1 Subnet Mask: 255.255.255.0 Default Gateway: 192.168.10.254 User Name: admin Password: admin System Login 1. Launch Internet Explorer. 2. Type http://192.168.10.1 and the IP address of the switch. Press Enter. 3. The login screen appears. 4. Enter username and password. The default username and password is admin. 5.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Main Interface Main interface System Information System Information interface System Information The system information will display the configuration of Basic Setting/Switch Setting page. Enable Location Alert Select Enable Location Alert and observe that the PWR1, PWR2 and FAULT LEDs of the switch will start to flash together. Select Disable Location Alert and the LEDs will stop flashing. INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Basic setting Switch Setting Switch setting interface Label Description System Name Assign the name of switch. The maximum length is 64 bytes System Description Display the description of switch. System Location Assign the switch physical location. The maximum length is 64 bytes System Contact Enter the name of contact person or organization Admin & Password This page allows you to configure the system password required to access the web pages.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ IP Setting You can configure the IP Settings and DHCP client function through IP configuration. IP Configuration interface Label Description DHCP Client To enable or disable the DHCP client function. When DHCP client function is enabling, the switch will be assigned the IP address from the network DHCP server. The default IP address will be replaced by the IP address that the DHCP server has assigned.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Time Setting The SNTP (Simple Network Time Protocol) settings allow you to synchronize switch clocks from the Internet. SNTP Configuration interface Label Description SNTP Client Enable or disable SNTP function to get the time from the SNTP server. Daylight Saving Time Enable or disable daylight saving time function. When daylight saving time is enabling, you need to configure the daylight saving time period.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Local Time Zone Conversion from UTC Time at 12:00 UTC November Time Zone - 1 hour 11 am Oscar Time Zone -2 hours 10 am ADT - Atlantic Daylight -3 hours 9 am AST - Atlantic Standard EDT - Eastern Daylight -4 hours 8 am EST - Eastern Standard CDT - Central Daylight -5 hours 7 am CST - Central Standard MDT - Mountain Daylight -6 hours 6 am MST - Mountain Standard PDT - Pacific Daylight -7 hours 5 am PST - Pacific Standard ADT - Alaskan
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ PTP Client The Precision Time Protocol (PTP) is a time-transfer protocol defined in the IEEE 1588-2002 standard that allows precise synchronization of networks (e.g., Ethernet). Accuracy within the nanosecond range can be achieved with this protocol when using hardware-generated timestamps.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Auto Provision Auto Provision allows you to automatically update the switch firmware. You can put the firmware or configuration file on TFTP server. When you reboot the switch, it will upgrade automatically. Before updating, make sure you have your TFTP server ready and the firmware image and configuration file is on the TFTP server. Auto Provision interface INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Backup & Restore You can save current EEPROM value from the switch to TFTP server, then go to the TFTP restore configuration page to restore the EEPROM value. Backup & Restore interface Label Description TFTP Server IP Address Fill in the TFTP server IP Restore File Name Fill the file name. Restore Select Restore to restore the configurations. Form Local PC User can select file restore, not need TFTP server .
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Redundancy DHCP Server DHCP Server – Setting The system provides with DHCP server function. Enable the DHCP server function and the switch system will be a DHCP server. DHCP Server Configuration interface Label Description DHCP Server Enable or Disable the DHCP Server function. Enable – the switch will be the DHCP server on your local network Start IP Address The dynamic IP assignment range.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ DHCP Server – Client List When the DHCP server function is activated, the system will collect the DHCP client information and display in here. DHCP Server Client Entries interface DHCP Server – Port and IP bindings You can assign the specific IP address that is in the assigned dynamic IP range to the specific port.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ DHCP Server –DHCP Relay Agent The DHCP relay agent relays DHCP messages between clients and servers for DHCP on different subnet domains. DHCP relay agent use Option 82 to insert specific information into a request that is being forwarded to a DHCP server and, according to Option 82, to remove the specific information from a reply packet when forwarding server DHCP packets to a DHCP client. Label Description DHCP Relay Enable/Disable DHCP Relay Agent.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Port Setting Port Control Set the state, speed/duplex, flow control, and security of the port. Port Control interface Label Description Port No. Port number for setting. State Enable/Disable the port. Speed/Duplex Set Auto-negotiation, 100-full, 100-half, 10-full or 10-half mode. Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Port Status The following information provides the current port status information. Port Status interface Rate Limit Limit the traffic of all ports, including broadcast, multicast and flooded unicast. You can also set Ingress or Egress to limit traffic received or transmitted bandwidth.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Port Trunk Port Trunk – Setting You can select static trunk or 802.3ad LACP to combine several physical links with a logical link to increase the bandwidth. Port Trunk - Setting interface Label Description Group ID Select port to join a trunk group. Type Support static trunk and 802.3ad LACP Work Port Select the number of active ports in dynamic group (LACP). The default value of works ports is maximum number of the group.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Port Trunk – Status Port Trunk - Status interface Label Description Group ID Trunk Group number Trunk Member Show Group port info INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ C-Ring C-Ring is the most powerful Redundant Ring in the world. The recovery time is less than 10ms. It can reduce unexpected damage caused by a network topology change. C-Ring supports three Ring topologies: C-Ring, Coupling Ring and Dual Homing. C-Ring interface INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Label Description Enable Ring Mark to enable Ring. Enable Ring Master There should be only one Ring Master in a ring. If there are two or more switches that set Ring Master to enable, the switch with the lowest MAC address will be the actual Ring Master and others will be Backup Masters. 1st Ring Port The primary port, when this switch is Ring Master. 2nd Ring Port The backup port, when this switch is Ring Master.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Legacy Ring Legacy Ring interface Legacy ring provides support for the switch to be used in an existing ring of ComNet X-Ring enabled switches. X-Ring provides a faster redundant recovery than Spanning Tree topology. The action is similar to STP or RSTP, but the algorithms between them are not the same.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ COM-Ring You can add ComNet switches into a network constructed by another ring technology and enable COM-Ring to cooperate with another vendor’s managed switch. ComRing interface Label Description Enable Enable the COM-Ring function Vendor Select the vendor whose ring you want to join 1st Ring Port Select the port that connects to the ring 2nd Ring Port Select the port that connects to the ring The application of COM-Ring is shown as below.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ C-RSTP C-RSTP is proprietary redundant ring technology invented by ComNet. Different from standard STP/RSTP, the recovery time of C-RSTP is <10ms and supports more nodes of connection in a ring topology. C-RSTP interface The application of C-RSTP is shown as below. PLC CNGE2FE8MSPOE+ CNGE2FE8MSPOE+ CNGE2FE8MSPOE+ IPC CNGE2FE8MSPOE+ CNGE2FE8MSPOE+ CNGE2FE8MSPOE+ Server CNGE2FE8MSPOE+ C-RSTP connection INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ RSTP The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol. It provides faster spanning tree convergence after a topology change. The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol. RSTP setting You can enable/disable RSTP function, and set parameters for each port.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Label Description Path Cost (1-200000000) The cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number 1 through 200,000,000. Port Priority (0-240) Decide that port should be blocked by priority in LAN. Enter a numerical value that is a multiple of 16, 0 through 240.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ MSTP Multiple Spanning Tree Protocol (MSTP) is a standard protocol base on IEEE 802.1s. The function is that several VLANs can be mapped to a reduced number of spanning tree instances because most networks do not need more than a few logical topologies. It supports loadbalancing schemes and the CPU is sparer than PVST (Cisco proprietary technology).
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ MSTP Port interface Label Description Port No. Select the port that you want to configure. Priority (0-240) Select which port should be blocked by priority in LAN. Enter a multiple of 16, 0 through 240. Path Cost (1-200000000) The cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number 1 through 200000000.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ MSTP Instance interface Label Description Instance Set the instance from 1 to 15 State Enable or disable the instance VLANs Set that VLAN will belong that instance Proprietary (0-61440) A value used to identify the root bridge. The bridge with the lowest value has the highest priority and is selected as the root. If the value changes, You must reboot the switch. The value must be a multiple of 4096 according to the protocol standard rule.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Multicast IGMP Snooping Internet Group Management Protocol (IGMP) is used by IP hosts to register their dynamic multicast group membership. IGMP has 3 versions, IGMP v1, v2 and v3. Please refer to RFC 1112, 2236 and 3376. IGMP Snooping improves the performance of networks that carry multicast traffic.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Static Multicast Filtering Static multicast filtering is the system by that end stations only receive multicast traffic if they register to join specific multicast groups. With multicast filtering, network devices only forward multicast traffic to the ports that are connected to registered end stations. Multicast Filtering Interface Label Description IP Address Assign a multicast group IP address within the range of 224.0.0.0 through 239.255.255.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ VLAN A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain that allows you to isolate network traffic. Only the members of the VLAN will receive traffic from the same members of VLAN. Basically, creating a VLAN from a switch is the logical equivalent of reconnecting a group of network devices to another Layer 2 switch. However, all the network devices are still physically plugged into the same switch.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Label Description VLAN Operation Mode Select VLAN Operation Mode: Disable, Port Base, 802.1Q GVRP Mode Enable/Disable GVRP function. Management VLAN ID Management VLAN can provide network administrator a secure VLAN to management Switch. Only the devices in the management VLAN can access the switch. Port Select the port to configure.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ VLAN Setting – Port Based Traffic is forwarded to the member ports of the same vlan group. vlan port based startup, set in the same group of the port, can be a normal transmission packet, without restricting the types of packets. VLAN Configuration – Port Base interface-1 The following table describes the labels in this screen. Label Description Add Click “add” to enter VLAN add interface.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ VLAN Configuration – Port Base interface-2 The following table describes the labels in this screen. Label Description Group Name VLAN name. VLAN ID Specify the VLAN ID Add Select port to join the VLAN group. Remove Remove port of the VLAN group Apply Click “Apply” to activate the configurations. Help Show help file. INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ SNMP Simple Network Management Protocol (SNMP) is the protocol developed to manage nodes (servers, workstations, routers, switches and hubs etc.) on an IP network. SNMP enables network administrators to manage network performance, find and solve network problems, and plan for network growth. Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ SNMPV3 Label Description Context Table Configure SNMP v3 context table. Assign the context name of context table. Select Apply to change context name User Table Configure SNMP v3 user table. User ID: set up the user name. Authentication Password: set up the authentication password. Privacy Password: set up the private password. Select Add to add context name. Select Remove to remove unwanted context name. Group Table Configure SNMP v3 group table.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ SNMP –Trap Setting A trap manager is a management station that receives traps, the system alerts generated by the switch. If no trap manager is defined, no traps will be issued. Create a trap manager by entering the IP address of the station and a community string. To define management stations as a trap manager and enter SNMP community strings and select the SNMP version.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Traffic Prioritization Traffic Prioritization includes 3 modes: port base, 802.1p/COS, and TOS/DSCP. By traffic prioritization function, you can classify the traffic into four classes for differential network application. IGS-3044GP(GC) series support 4 priority queues. Qos policy Traffic Prioritization interface Label Description QOS Mode Port-base: the output priority is determined by ingress port.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Port-base priority Port-based Priority interface Priority Assign Port with one of four available priority queues: High, Middle, Low, and Lowest. Apply Select Apply to set the configurations. Help Show help file. INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ COS/802.1p COS/802.1p interface COS/802.1p COS (Class Of Service) is also known as 802.1p. It describes that the output priority of a packet is determined by the user priority field in 802.1Q VLAN tag. The priority value is supported 0to7.COS value map to 4 priority queues: High, Middle, Low, and Lowest. COS Port Default When an ingress packet has no VLAN tag, a default priority value is considered and determined by ingress port.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ TOS/DSCP TOS/DSCP interface TOS/DSCP TOS (Type of Service) is a field in the IP header of a packet. This TOS field is also used by Differentiated Services and is called the Differentiated Services Code Point (DSCP). This field can determine the output priority of a packet and the priority value is supported 0to63. DSCP value map to 4 priority queues: High, Middle, Low, and Lowest. Apply Select Apply to set the configurations. Help Show help file.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Security Five useful functions can enhance security of switch: IP Security, Port Security, MAC Blacklist, and MAC address Aging and 802.1x protocol. Management Security Only IP in the Secure IP List can manage the switch through your defined management mode. (WEB, Telnet, SNMP) IP Security interface Label Description IP security MODE Enable/Disable the IP security function. Enable WEB Management Mark the blank to enable WEB Management.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Static MAC Forwarding Static MAC Forwarding is to add static MAC addresses to hardware forwarding database. If port security is enabled at Port Control page, only the frames with MAC addresses in this list will be forwarded, otherwise will be discarded. Port Security interface Label Description MAC Address Input MAC Address to a specific port. Port NO. Select port of switch. Add Add an entry of MAC and port information. Delete Delete the entry.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ MAC Blacklist MAC Blacklist can eliminate the traffic forwarding to specific MAC addresses in list. Any frames forwarding to MAC addresses in this list will be discarded. Thus the target device will never receive any frame. MAC Blacklist interface Label Description MAC Address Input MAC Address to add to MAC Blacklist. Port NO. Select port of switch. Add Add an entry to Blacklist table. Delete Delete the entry. Help Show help file.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ 802.1x 802.1x - Radius Server 802.1x makes the use of the physical access characteristics of IEEE802 LAN infrastructures in order to provide a authenticated and authorized devices attached to a LAN port. Please refer to IEEE 802.1X - Port Based Network Access Control. 802.1x Radius Server interface Label Description Radius Server Setting 802.1x Portocol Enable or Disable 802.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Server Timeout Set the period of time the switch waits for a Radius server response to an authentication request. Max Requests Set the maximum number of times to retry sending packets to the supplicant. Re-Auth Period Set the period of time after that clients connected must be re-authenticated. Apply Select Apply to set the configurations. Help Show help file. INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ 802.1x-Port Authorized Mode Set the 802.1x authorized mode of each port. 802.1x Port Authorize interface Label Description Port Authorized Mode Reject: force this port to be unauthorized. Accept: force this port to be authorized. Authorize: the state of this port was determined by the outcome of the 802.1x authentication. Disable: this port will not participate in 802.1x. Apply Select Apply to set the configurations. Help Show help file.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ 802.1x-Port Authorized Mode Show 802.1x port authorized state. 802.1x Port Authorize State interface TACACS+ INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Warning Warning: function is very important for managing the switch. You can manage the switch by SYSLOG, E-MAIL, and Fault Relay. It helps monitor the switch status on remote site. When events occur, the warning message will be sent to your appointed server, E-MAIL, or relay fault to switch panel. System alarm supports two warning modes: 1. SYSLOG. 2. E-MAIL. You can monitor the switch through selected system events.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ System Warning – SMTP Setting The SMTP is Short for Simple Mail Transfer Protocol. It is a protocol for e-mail transmission across the Internet. Please refer to RFC 821 - Simple Mail Transfer Protocol. System Warning – SMTP Setting interface Label Description E-mail Alart Enable/Disable transmission system warning events by Email.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ System Warning – Event Selection SYSLOG and SMTP are the two warning methods that supported by the system. Check the corresponding box to enable system event warning method you wish to choose. Please note that the checkbox cannot be checked when SYSLOG or SMTP is disabled. System Warning – Event Selection interface Label Description Device cold start When the device executes cold start, the system will issue a log event.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Monitor and Diag MAC Address Table Refer to IEEE 802.1 D Sections 7.9. The MAC Address Table, that is Filtering Database, supports queries by the Forwarding Process, as to whether a frame received by a given port with a given destination MAC address is to be forwarded through a given potential transmission port. MAC Address Table interface Label Description Port NO. : Show all MAC addresses mapping to a selected port in table.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Port Overview Port statistics show several statistics counters for all ports Port Overview interface Label Description Type Show port speed and media type. Link Show port link status. State Show ports enable or disable. TX GOOD Packet The number of good packets sent by this port. TX Bad Packet The number of bad packets sent by this port. RX GOOD Packet The number of good packets received by this port.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Port Monitoring Port monitoring function supports TX (egress) only, RX (ingress) only, and both TX/RX monitoring. TX monitoring sends any data that egress out checked TX source ports to a selected TX destination port as well. RX monitoring sends any data that ingress in checked RX source ports out to a selected RX destination port as well as sending the frame where it normally would have gone.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ System Event Log If system log client is enabled, the system event logs will be shown in this table. System event log interface Label Description Page Select LOG page. Reload To get the newest event logs and refresh this page. Clear Clear log. Help Show help file. INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Power over Ethernet (PoE) System setting The following interface is the PoE setting interface. There are 8 ports (port 1 to port 8) act as PSE (Power Supply Equipment) ports. Label Description Maximum Power Budget Set the maximum power available. Power Limit Mode Max of AF/AT: Automatically detects the Powered Device (PD) and selects the most suitable mode.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Power over Ethernet - Port Control The following interface is the PoE setting interface. There are 8 ports (port 1 to port 8) act as PSE (Power Supply Equipment) ports. Label Description Port Port number. Enable state Mark the checkbox to enable PoE function for specific ports Priority Set port priority for the PoE power management. 1 = C (critical), 2 = H (High), 3 = L (Low) Power Limit Set the power limit value.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Port Status This screen shows detailed PoE status for each Port. Label Description Port Port number State Show PSE Status Current(mA) Displays current value Voltage(V) Displays voltage value Power(mW) Displays watt value Determined Class Displays the power class. If the Bypass classification is enabled, the class value will not show in here. INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Save Configuration If any configuration is changed, visit this screen and save current configuration data to the permanent flash memory. Otherwise, the current configuration will be lost when power is turned off or the system is reset. System Configuration interface Label Description Save Save all configurations. Help Show help file. Factory Default Factory Default interface Reset switch to default configuration.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Command Line Interface Management About CLI Management Besides WEB-base management, CNGE2FE8MSPOE+ also supports CLI management. You can use console or telnet to management switch by CLI. CLI Management by RS-232 Serial Console (9600, 8, none, 1, none) Before Configuring by the RS-232 serial console, use an RJ45 to DB9-F cable to connect the Switch’s RS-232 Console port to your PCs’ COM port.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Step 2. Input a name for new connection Step 3. Select to use COM port number INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Step 4. T he COM port properties setting, 9600 for Bits per second, 8 for Data bits, None for Parity, 1 for Stop bits and none for Flow control. Step 5. T he Console login screen will appear. Use the keyboard to enter the Username and Password (same as for accessing via Web Browser), and then press Enter. INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ CLI Management by Telnet. Users can use telnet to configure the switches. The default value is as below: IP Address: 192.168.10.1 Subnet Mask: 255.255.255.0 Default Gateway: 192.168.10.254 User Name: admin Password: admin Follow the steps below to access the console via Telnet. Step 1. T elnet to the IP address of the switch from the Windows Run command (or from the MS-DOS prompt). Step 2. The Login screen will appear.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Level Modes Access Method Prompt Exit Method About This Model User EXEC Begin a session switch> with your switch. Enter logout or The user command available quit. at the level of user is the subset of those available at the privileged level. Use this mode to • Enter menu mode. • Display system information. Privileged EXEC Enter the enable switch# command while in user EXEC mode. Enter disable to The privileged command is exit.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Symbol of Command Level.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ dhcpserver enable G Enable DHCP Server switch(config)#dhcpserver enable dhcpserver lowip [Low IP] G Configure low IP address for IP pool switch(config)# dhcpserver lowip 192.168.1.1 dhcpserver highip [High IP] G Configure high IP address for IP poolswitch(config)# dhcpserver highip 192.168.1.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—Port Commands Set Commands Level Description Example switch(config)#interface fastEthernet 2 interface fastEthernet [Portid] G Choose the port for modification. duplex [full | half] I Use the duplex configuration switch(config)#interface fastEthernet 2 command to specify the duplex switch(config-if)#duplex full mode of operation for Fast Ethernet.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ state [Enable | Disable] I Use the state interface configuration switch(config)#interface fastEthernet 2 command to specify the state mode switch(config-if)#state Disable of operation for Ethernet ports. Use the disable form of this command to disable the port.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—Trunk command set Commands Level Description Example aggregator priority [1to65535] G Set port group system priority switch(config)#aggregator priority 22 aggregator activityport [Port Numbers] G Set activity port switch(config)#aggregator activityport 2 aggregator group [GroupID] [Port-list] lacp workp [Workport] G Assign a trunk group with LACP switch(config)#aggregator group 1 1-4 active.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—VLAN command set Commands Level Description Example vlan database P Enter VLAN configure mode switch#vlan database vlan [8021q | gvrp] V To set switch VLAN mode. switch(vlan)# vlanmode 802.
INSTALLATION AND OPERATION MANUAL Commands Level CNGE2FE8MSPOE+ Description Example spanning-tree enable G Enable spanning tree switch(config)#spanning-tree enable spanning-tree priority [0to61440] G Configure spanning tree priority parameter switch(config)#spanning-tree priority 32767 spanning-tree max-age [seconds] G Use the spanning-tree max-age switch(config)# spanning-tree max-age 15 global configuration command to change the interval between messages the spanning tree receives from the
INSTALLATION AND OPERATION MANUAL no spanning-tree G Disable spanning-tree.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—IGMP command set Commands Level Description Example igmp enable G Enable IGMP snooping function switch(config)#igmp enable Igmp-query auto G Set IGMP query to auto mode switch(config)#Igmp-query auto Igmp-query force G Set IGMP query to force mode switch(config)#Igmp-query force show igmp configuration P Displays the details of an IGMP configuration.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—MAC/Filter Table command set Commands Level Description Example mac-address-table static hwaddr [MAC] I Configure MAC address table of interface (static).
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—SNMP command set Commands Level Description Example snmp agent-mode [v1v2c | v3] G Select the agent mode of SNMP switch(config)#snmp agent-mode v1v2c snmp-server host [IP address] community [Community-string] trap-version [v1|v2c] G Configure SNMP server host information and community string switch(config)#snmp-server host 192.168.10.50 community public trapversion v1 (remove) Switch(config)# no snmp-server host 192.168.10.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—Port Mirroring command set Commands Level Description Example monitor rx G Set RX destination port of monitor function switch(config)#monitor rx monitor tx G Set TX destination port of monitor function switch(config)#monitor tx show monitor P Show port monitor information switch#show monitor monitor [RX|TX|Both] I Configure source port of monitor function switch(config)#interface fastEthernet 2 switch(config-if)#monitor R
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—802.1x command set Commands Level Description Example 8021x enable G Use the 802.1x global configuration switch(config)# 8021x enable command to enable 802.1x protocols. 8021x system radiousip [IP address] G Use the 802.1x system radious IP global configuration command to change the radious server IP. switch(config)# 8021x system radiousip 192.168.1.1 8021x system serverport [port ID] G Use the 802.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—TFTP command set Commands Level Description Example backup flash:backup_cfg G Save configuration to TFTP and need switch(config)#backup flash:backup_cfg to specify the IP of TFTP server and the file name of image. restore flash:restore_cfg G Get configuration from TFTP server and need to specify the IP of TFTP server and the file name of image.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ event ComRing-topologychange [Systemlog|SMTP|Both] G Set s ring topology changed event type switch(config)#event ring-topology-change both event systemlog [Link-UP|Link-Down|Both] I Set port event for system log switch(config)#interface fastethernet 3 switch(config-if)#event systemlog both event smtp [Link-UP|Link-Down|Both] I Set port event for SMTP switch(config)#interface fastethernet 3 switch(config-if)#event smtp both show event P Show ev
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List—SNTP command set Commands Level Description Example sntp enable G Enable SNTP function switch(config)#sntp enable sntp daylight G Enable daylight saving time, if SNTP switch(config)#sntp daylight function is inactive, this command can’t be applied. sntp daylight-period [Start time] [End time] G Set period of daylight saving time, if SNTP function is inactive, this command can’t be applied.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Commands Set List — C-Ring command set Commands Level Description Example Ring enable G Enable C-Ring switch(config)# ring enable Ring master G Enable ring master switch(config)# ring master Ring couplering G Enable couple ring switch(config)# ring couplering Ring dualhoming G Enable dual homing switch(config)# ring dualhoming Ring ringport [1st Ring Port] [2nd Ring Port] G Configure 1st/2nd Ring Port switch(config)# ring ringport 7 8
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Technical Specifications Physical Ports 10/100 BASE-T(X) Ports in RJ45 Auto MDI/MDIX with PSE 8 ports supporting IEEE 802.3at compliant PoE Total power budget is 240W with maximum 30W per port) Gigabit Combo Ports with 10/100/1000BASE-T(X) and 100/1000BASE-X SFP port 2 Technology Ethernet Standards IEEE 802.3 for 10BASE-T IEEE 802.3u for 100BASE-TX and 100BASE-FX IEEE 802.3z for 1000BASE-X IEEE 802.3ab for 1000BASE-T IEEE 802.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ Software Features STP/RSTP/MSTP (IEEE 802.1D/w/s) Redundant Ring (C-Ring) with recovery time < 10ms over 250 units TOS/Diffserv supported Quality of Service (802.1p) for real-time traffic VLAN (802.
INSTALLATION AND OPERATION MANUAL Weight CNGE2FE8MSPOE+ 1100g / 2.
INSTALLATION AND OPERATION MANUAL CNGE2FE8MSPOE+ INS_CNGE2FE8MSPOE+_REV– TECH SUPPORT: 1.888.678.
MECHANICAL INSTALLATION INSTRUCTIONS ComNet Customer Service Customer Care is ComNet Technology’s global service center, where our professional staff is ready to answer your questions at any time. Email ComNet Global Service Center: customercare@comnet.net 3 CORPORATE DRIVE | DANBURY, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.