User Manual

INS_CNGEMC4+2[POE][HO]/M 09/08/20 PAGE 13
INSTALLATION AND OPERATION MANUAL CNGEMC4+2[POE][HO]/M
TECH SUPPORT: 1.888.678.9427
DIP Switches
The CNGEMC4+2 media converters features DIP switch based operation of MUX and RSFP.
The DIP Switches are located on the back of the units and are numbered from left to right
when viewing the side of the media converter with the backplate on the bottom and the power
connections on the left. If “Web Management Enabled” is selected in management software
under Systems settings, the DIP Switch settings on the media converter will be overridden by any
settings made int he browser interface.
DIP Switch
Position Description
1 MUX
2 RSFP
Dip Switch Feature Summary
MUX
(switch 1) Resulting Mode Comment
Off No Port Isolation
All Ports Communicating
On MUX Enabled
Ports 1-4 are isolated and only transmit out the fiber ports
RSFP
(switch 2) Resulting Mode Comment
Off Fiber Ports are
independent
All Ports Communicating
On Fiber Ports 5 and 6
are Trunked
Port 6 is primary, Port 5 is failover