Installation Manual
Table Of Contents
- About This Guide
- Overview
- Hardware Overview
- Ethernet Cables
- WEB Management
- Configuration by Web Browser
- About Web-based Management
- Basic Setting
- System Information
- Admin & Password
- Auth Method
- IP Setting
- HTTPS
- SSH
- LLDP
- Backup/Restore Configuration
- Firmware Update
- DHCP Server
- Port Setting
- Port Trunk
- LACP
- Redundancy
- MSTP
- STP
- VLAN
- VLAN Setting Example
- SNMP
- Traffic Prioritization
- Multicast
- Security
- AAA
- RADIUS Overview
- Warning
- System Warning
- Monitor and Diag
- Port Statistic
- System Log Information
- Cable Diagnostics
- SFP Monitor
- Ping
- Syncronization-PTP
- PoE Configuration
- Status
- Factory Defaults
- System Reboot
- Configuration by Web Browser
- Command Line Interface Management
- Technical Specifications
INS_CWGE26FX2TX24MSPOE_REV– 5 Mar 2014 PAGE 108
INSTALLATION AND OPERATION MANUAL CWGE26FX2TX24MSPOE
TECH SUPPORT: 1.888.678.9427
Cable Diagnostics
This page is used for running the VeriPHY Cable Diagnostics.
Press Start to run the diagnostics. This will take approximately 5 seconds. If all ports are selected,
this can take approximately 15 seconds. When completed, the page refreshes automatically, and
you can view the cable diagnostics results in the cable status table. Note that VeriPHY is only
accurate for cables of length 7 – 140 meters.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore, running VeriPHY
on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is
complete.
Label Description
Port The port where you are requesting VeriPHY Cable Diagnostics.
Cable Status Port: Port number.
Pair: The status of the cable pair.
Length: The length (in meters) of the cable pair.