Installation Manual

TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL RLMCSFP SERIES
INS_RLMCSFP_REV–
Rev. 27 Jun 2016 PAGE 4
INSTALLATION AND OPERATION MANUAL RLMCSFP SERIES
7 - CONNECT POWER
Connect power to unit per the following table.
Table 3 – Power Connections per Use Case
RLMCSFP24DC RLMCSFP48DC RLMCSFPHV
Operating Voltage
Redundant Inputs
9 to 36 VDC (max)
Redundant Inputs
36 to 59 VDC (max)
88 to 300 VDC (max)
OR
85 to 264 VAC (max)
Use Power Connectors
Vin1+ and Vin1- for PS 1
Vin2+ and VIN2- for PS 2
Vin1+ and Vin1- for PS 1
Vin2+ and VIN2- for PS 2
+/L, -/N, and Earth GND
Contact the ComNet Design Center, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.
8 - VERIFY FUNCTIONALITY
See LED Indicator table below and Troubleshooting Guide if corrective action is needed.
Table 4 – Front Panel LED Indicators
SFP Link SFP Speed Fault Power
GREEN Solid Communication link has been established
over optical fiber. Flashes when data is
being transmitted.
1000 Mbps No Fault (NC-
COM)
Power Applied
Flashing Fiber failure or copper failure (Link Fault
Enable must be switched set to ON)
RED Solid 100 Mbps Fault (NO-COM)
OFF Communication link has not been
established.
Unit is not correctly powered up or DIP
Switch incorrectly set.
(Reset power after switch change.)
Unit is not
correctly
powered up
Unit is not
correctly
powered up
Figure 5Electrical Port
Ethernet
Speed
Ethernet
Link /
Activity
Installation Instructions (Continued)
Figure 6 - Fault Relay Operation
The fault relay is normally closed and will open on any of the following alarm conditions:
- Link Fault is enabled on the remote RLMCSFP unit and the corresponding copper port has been
disconnected.
- Link Fault is enabled on the local RLMCSFP unit and the corresponding copper port has been
disconnected.
- Fiber Fault is enabled on the local RLMCSFP unit and the fiber link is down or the power has been lost to
either the local or remote RLMCSFP unit.
Table 6 – Troubleshooting Guide
Problem Steps to Take
Power LED not lighting Check that power is properly applied to the unit using the correct connector pair.
No Communication Check Ethernet Link LEDs, Fiber Optic Link LEDs. Confirm Connections, DIP switches are set properly. Verify that the Data Rate switches are set
to the same data rate on back-to-back units and match the installed SFP. Restart the unit if the Data Rate Switch or installed SFP has changed.
Table 5 – Electrical Port LED Indicators
Link / Activity
Speed
GREEN Solid Communication link has been established over the electrical cable
Flashing Data is being transmitted over the electrical cable
YELLOW 1000 Mbps Speed
OFF Communication link has not been established. 10/100 Mbps Speed