Installation Manual
INS_RLXE4GE24MODMS_REV– 20 Dec 2017 PAGE 61
INSTALLATION AND OPERATION MANUAL RLXE4GE24MODMS
TECH SUPPORT: 1.888.678.9427
Object Description
Domain The domain of the client layer flow.
For a MPLS MEP, the client domain can only be EVC or LSP. For a non-MPLS MEP, the
client flow domain can not be LSP. For a non-MPLS MEP, the client flow domain can not
be mixed VLAN and EVC.
Instance Client layer flow instance numbers.
Level Client layer level - AIS and LCK PDU transmitted in this client layer flow will be on this
level.
AIS Prio The priority to be used when transmitting AIS in each client flow. Priority resulting in
highest possible PCP can be selected.
LCK Prio The priority to be used when transmitting LCK in each client flow. Priority resulting in
highest possible PCP can be selected.
AIS
Enable Insertion of AIS signal (AIS PDU transmission) in client layer flows, can be enable/
disabled.
Frame Rate Selecting the frame rate of AIS PDU. This is the inverse of transmission period as
described in Y.1731.
Protection Selecting this means that the first 3 AIS PDU is transmitted as fast as possible - in case of
using this for protection in the end point.
LOCK
Enable Insertion of LOCK signal (LCK PDU transmission) in client layer flows, can be enable/
disabled.
Frame Rate Selecting the frame rate of LCK PDU. This is the inverse of transmission period as
described in Y.1731.:
Refresh Click to refresh the page immediately.
Back Click to go back to this MEP instance main page.
Apply Click to apply changes.
Reset Click to undo any changes made locally and revert to previously saved values.