Installation Manual
INS_RLXE4GE24MODMS_REV– 20 Dec 2017 PAGE 65
INSTALLATION AND OPERATION MANUAL RLXE4GE24MODMS
TECH SUPPORT: 1.888.678.9427
Measurement Bins for
IFDV
Configurable number of Inter-Frame Delay Variation Measurement Bins per
Measurement Interval.
The minimum number of FD Measurement Bins per Measurement Interval
supported is 2.
The maximum number of FD Measurement Bins per Measurement Interval
supported is 10.
The default number of FD Measurement Bins per Measurement Interval supported
is 2.
Measurement
Threshold
Configurable the Measurement Threshold for each Measurement Bin.
The unit for a measurement threshold is in microseconds (us).
The default configured measurement threshold for a Measurement Bin is an
increment of 5000 us.
Delay Measurement Bins for FD
A Measurement Bin is a counter that stores the number of delay measurements falling within a specified
range, during a Measurement Interval.
If the measurement threshold is 5000 us and the total number of Measurement Bins is four, we can give
an example as follows.
Bin Threshold Range
bin0 0 us 0 us <= measurement < 5,000 us
bin1 5,000 us 5,000 us <= measurement < 10,000
us
bin2 10,000 us 10,000 us <= measurement < 15,000
us
bin3 15,000 us 15,000 us <= measurement < infinite
us
Delay Measurement Bins for IFDV
A Measurement Bin is a counter that stores the number of delay measurements falling within a specified
range, during a Measurement Interval.
If the measurement threshold is 5000 us and the total number of Measurement Bins is four, we can give
an example as follows.
Bin Threshold Range
bin0 0 us 0 us <= measurement < 5,000 us
bin1 5,000 us 5,000 us <= measurement < 10,000
us
bin2 10,000 us 10,000 us <= measurement < 15,000
us
bin3 15,000 us 15,000 us <= measurement < infinite
us
Refresh Click to refresh the page immediately.
Back Click to go back to this MEP instance main page.
Apply Click to apply changes.
Reset Click to undo any changes made locally and revert to previously saved values.










