coffee grinders instructions manual PROFESSIONAL ESPRESSO K3 K8 SILENZIO K3 ELITE K10 CONIC K6 K10 CONIC PB K6 SILENZIO K10 MASTER CONIC K6 PB K10 MASTER CONIC PB
index 1. SAFETY MEASURES 1 2. DESCRIPTION 2 3. INSTRUCTIONS 3 4. IDENTIFICATION 3 5. TECHNICAL CARACTERISTICS 4 6. INSTALLATION 6 7. REGULATION 8 8. OPERATION 10 9. CONFIGURATION 13 10. CLEANING 14 11. MAINTENANCE 16 12.
1. SECURITY NOTE: The manufacturer will not be held responsible for any damages resulting from improper use of the equipment, or for not following the safety measures as outlined below. Safety measures incorporated into our grinders: • Special screw to maintain the hopper fixed in place. • Access restrictor in the grind group.
SOUND DECIBEL LEVEL The level of sound emitted in different models is: Sound decibel level With coffee K3, K3 ELITE 75,3 dB K6, K6 PB 73,2 dB K6 SILENZIO 68,7 dB K8 SILENZIO 70,2 dB K10 CONIC, K10 CONIC PB 68,4 dB K10 MASTER CONIC, K10 MASTER CONIC PB 67,8 dB 2. DESCRIPTION Your new grinder has been designed using the most sophisticated technologies in existence. The result is a product of high quality that offers the assurance of the best results possible.
3. INSTRUCTIONS 3.1. This manual is designed to provide the necessary information to correctly install, use and maintain the grinder, as well as to highlight precautions for users to keep in mind. To ensure the best operation of the coffee grinder, please follow the instructions as outlined in this manual. This manual should be saved for the life of the grinder, and should always be at the disposal of the operator. 3.2.
5. TECHNICAL CARACTERISITICS 5.1. Usage The coffee grinders are intended for use on commercial premises and facilities where ground coffee is required, or in small stores that sell coffee. The grinder must only be used to grind coffee beans. Any use other than this will be considered improper and dangerous. NOTE: The manufacturer will not be held responsible for any damages resulting from improper use of the equipment, or for not following the safety measures as outlined below. 5.2.
Model K6, K6 SILENZIO, K6 PB K8 SILENZIO 2.3 2.5 3.3 2.65 2.65 58 64 83 Conic 68 Conic 68 Production* 50Hz 8.2 13 33 33 37 3,7 6 15 15 17 Production* 60Hz 9.5 15 38.5 38.5 44 4,3 7 17,5 17,5 20 Hopper capacity 1.76 3.74 3.74 3.74 3.74 38.5 1700 1700 1700 1700 Ø Burrs Mini-hopper capacity (optional) K10 CONIC, K10 CONIC PB K10 MASTER CONIC, K10 MASTER CONIC PB K3, K3 ELITE lb/h Kg/h lb/h Kg/h 0.6 0.6 0.6 0.6 275 275 275 275 Doser capacity 0.66 0.
6. EXTERNAL COMPONENTS K10 MASTER CONIC 6 ORIGINAL INSTRUCTIONS | Ref. quality process 002/03 | v.
K3 ELITE K01068 | v. 22/09/2014 | Ref.
7. INSTALLATION 7.1. General Warnings The person installing the grinder should carefully read this instruction manual before installation. The installation of this machine should be completed by qualified and authorized personnel, and all norms of safety and sanitation should be followed. 7.2. Important Warnings The operator of the grinder should be a responsible adult, and a never a minor or person incapable of safely using such equipment.
7.3. Where to use The grinder should be installed on a flat, stable surface. The minimum dimensions of the work space should be as follows: Height Model Width Depth K3, K3 ELITE 20.27 515 7.28 185 15.15 385 K3, K3 ELITE Mini-hopper (optional) 17.32 440 7.28 185 15.15 385 K6, K6 SILENZIO, K6 PB 25.78 655 9.25 235 16.53 420 K8 SILENZIO 25 655 9.25 235 16.53 420 K10 CONIC, K10 CONIC PB 25 655 9.25 235 16.53 420 28.1 735 9.25 235 16.
8. REGULATION 8.1. Grinder set up Place the hopper ( ) on the grind regulator ( ) and make sure the bean trap ( ) is in the closed position. Lock the hopper ( ) in place using a flat head screw driver to gently tighten the hopper security screw making it match to the hole at the bean hopper collar ( ) (Fig. 1). Remove the hopper lid ( hopper ( ) (Fig. 2).
8.2. Grind adjustment system 8.2.1. Micrometrical system / Parallel micrometrical system Rotate the grind regulator ( ) until reaching the grind level desired. Rotating the grind regulator counterclockwise will result in a courser grind; turning the regulator clockwise will result in a finer grinder* (Fig. 3). Once you reach the desired grinding point, you can fix the grinding regulation ( using the regulation break ( ) (Fig. 4). Except K3 and K3 ELITE models.
NOTE: If the output is very slow, it could mean that the coffee is being ground too fine. If the output is very fast, it could mean that the coffee is being ground too coarse. A perfect espresso grind is found when the grind point gives an infusion of 25 ml of coffee in 25 seconds using 7 grams of ground coffee. 8.3.
9. OPERATION 9.1. Main switch The main swith ( ) has 2 positions of use, ON–OFF ON: Working OFF: Not working 9.2. Use To turn the machine on and off use the ON–OFF switch ( ). The machine will start to grind the coffee. If the automatic stop option is incorporated, the grinder will stop grinding when the dispenser reaches the maximum level, and will restart after 8 portions of coffee have been served, grinding again to the maximum level.
9.4. Telescopic press When using the telescopic coffee press option, place the portafilter on the fork ( ) and push the coffee tamper downwards (Fig. 8). 10. CLEANING 10.1. General cleaning To ensure that the grinder functions properly, and produces the highest quality grind possible, the parts that come into contact with coffee should cleaned periodically. General Cleaning guidelines as follows: • Always turn the main power switch to the OFF position ( ). • Unplug the machine from the power source.
The steps to follow are: • In order to properly clean the bean hopper , first empty out all remaining beans and fragments. • Close the bean trap on the hopper ( grind chamber. ) and grind out the remaining coffee in the • Remove any remaining coffee beans from the bean hopper ( ). • Pour the recommended grinder cleaning product into the bean hopper ( ) and open the bean trap ( ), allowing the cleaning product to pass into the grind chamber.
11. MAINTENANCE 11.1. General warning Before performing any type of maintenance you should: • Always turn OFF the main power switch to the OFF position ( ). • If the grinder is jammed, unplug it from the power source and contact an authorized service technician. Not following these warnings can compromise the safety of the grinder as well as the user. 11.2.
11.3. Grinding group maintenance Not following the recommended burr life guidelines can compromise the safety of the grinder. These operations should be done by a qualified service tecnician. To perform grind chamber maintenance please observe the following steps: Turn off the grinder by making sure the main power switch ( ) is on the OFF position. Disconnect the plug from the power source. Loosen the hopper security screw ( ) using a flat head screw driver as seen in Fig.1.
Rotate the grind regulator clockwise until it is completely unscrewed (Fig. 11) until the upper and lower burrs touch and can not be turned further. Clean the grind chamber and threads of the housing using a soft cloth and vacuum cleaner until all of the oils and residue has been removed. Make sure to put new food grade lubricant on the clean threading of the housing and upper assembly. Insert the upper burr assembly into the grind chamber, and turn counter clockwise.
11.3.1. Models with flat burrs (K3, K6 and K8) Position the regulator collar ( ) leaving about 45º between the grind point lock screw ( ) and regulator limit stop (Fig. 13). In that position, tighten the regulator ( ) on the upper burr carrier and with an Allen key A3 series for the K3 (Fig. 9), or a T20 Torx screwdriver for the other models, as Fig. 10. For the models with the micrometric Parallel system, first make sure that the grind point lock screw ( ) is lined up with the locking foot.
11.3.2. Models with conical burrs (K10) Position the regulator collar ( ) leaving about 90º between the grind point lock screw ( ) and regulator limit stop (Fig. 14). In that position, tighten the regulator ( ) on the upper burr carrier and with a T20 Torx screwdriver, as Fig. 10. For the models with the micrometric Parallel system, first make sure that the grind point lock screw ( ) is lined up with the locking foot.
12. EC CONFORMITY In accordance with European commu-nity directives, quality certificates have been applied. All materials have been adapted and technical reports are available at our offices. 04/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. 06/42/EC amending Directive 89/392/EC on the approximation of the laws of the Member States relating to machinery REG.