User manual
page 27
Cyclon Series User Manual β CommissioningCyclon Series User Manual β Commissioning
1.2 Pressure Calibration
Note: The values shown throughout these procedures are examples only. Ensure set values are compatible
with the compressor model.
No. Action Reason Display
1. Switch power βONβ at the isolator 0.0 Bar
and allow the controller to initialise.
2. Press the
STOP
button. 0.0 Bar
even if the compressor is already
stopped.
3. Disconnect the air pipe To apply 0.0 Bar to the 0.0 Bar
from the pressure transmitter. pressure transmitter
4. Press and hold the
STOP
, To enter the Pressure 0.0 Bar
PLUS
and
MINUS
buttons calibration mode
together.
5. After five seconds indicators To enter Pressure calibration 0.0 Bar
L1 to L8 will flash four times. mode. The 0.0 Bar calibration
When the indicators start to set point is automatically set when
flash release the
STOP
,
PLUS
pressure calibration mode is
and
MINUS
buttons. entered.
6. Apply an accurately known (example - 7.0 bar) 7.1 Bar
pressure, above 5.5 Bar, to
the pressure transmitter.
7. Press
PLUS
or
MINUS
until To calibrate the pressure 7.0 Bar
the pressure display matches transmitter to the applied
the applied pressure. pressure.
8. Press
STOP
To enter the pressure calibration 7.0 bar
into the controller memory.
(The display will return to normal
running mode).
9. Remove the slave air supply and 0.0 Bar
re-connect the air pipe to the
pressure transmitter.