1.3 Checking/Altering Program Mode Values
Note: The values shown throughout these procedures are examples only. Ensure set values relate to
compressor model.
No. Action Reason Display
1. Switch power ‘ON’ at the isolator 0.0 Bar
and allow the controller to initialise.
2. Press the
STOP
button, even if 0.0 Bar
the compressor is already stopped.
3. Press and hold the
PLUS
and To enter Program mode 0.0 Bar
MINUS
buttons together.
4. After five seconds indicators 0.0 Bar
L1 to L8 will flash four times.
When the indicators start to
flash release the
PLUS
and
MINUS
buttons.
5. Indicator L1 will light and the display 7.5 Bar
will show the upper pressure
set point P1.
6. Press
PLUS
or
MINUS
To adjust the displayed value 7.0 bar
or go to step 8 if no adjustment
required. (pulsing display)
7. Press
STOP
To program the new value 7.0 bar
into the controller memory
(steady display )
8. Press
VIEW
To step to the next option 115°C
9. Indicator L2 will light and the display 115°C
will show the oil temperature trip
set point.
10. Press
PLUS
or
MINUS
To adjust the displayed value 110°C
or go to step 12 if no adjustment
required. (pulsing display)
11. Press
STOP
To program the new value 110
°
C
into the controller memory
(steady display)
12. Press
VIEW
To step to the next option
13. Indicator L3 will light and the 2000
display will show the maximum
service interval timer setting.