User manual

CompAir BroomWade Limited
page 32
No. Action Reason Display
13. Check that the compressor automatically
re-starts when pressure falls below the
lower pressure set point P2.
14. Run the compressor for 30 minutes.
Check for air/oil leaks. (It will be
necessary to remove the enclosure
panels for short periods). Stop the
compressor and rectify any leaks.
WARNING: RISK OF HIGH PRESSURE
Do not use hands to locate leaks in the
system. Always use a piece of paper or
card for this purpose.
15. Stop the compressor and check that all
enclosure panels are secure.
!