1.7 Alarms and Shutdown Trips
1. If an alarm condition occurs and service
attention is required the appropriate alarm
indicator will flash.
2. If a trip condition occurs the compressor will
stop and the appropriate trip indicator will
flash. This can occur any time after the
compressor has been started. See para 1.9
‘Control panel indicators’.
3. The oil temperature alarm and oil
temperature trip conditions are shown by
indicator (L2) flashing. Indicator (L2) will flash
slowly for an alarm condition and the
compressor will continue to run. Indicator (L2)
will flash quickly for a trip condition and the
compressor will shut down immediately.
4. The oil temperature alarm level is
automatically set 10°C below the
programmed oil temperature trip level. See
para 2 ‘Program mode’.