User manual

page 49
Cyclon Series User Manual – Maintenance
Item Action
Weekly
Oil System Check oil level. Top up if necessary.
Separator Element Check separator element. Renew if on load pressure
differential is 1 bar or above.
Aftercooler Check condition of pre-filter and clean as necessary.
Minor Service – Every 2000 hours or 6 months (whichever is sooner)
Minor Service Use correct Service kit for model.
Oil System Change oil if appropriate to type in use (see 3.4 ‘Oil
System’).
Blowdown System Check operation.
Electrical Wiring Check connections and condition.
Drain Solenoid Valve Check operation.
Starter Check connections and condition of contactors.
Aftercooler and Oil Cooler Clean externally.
Drive Belt(s) Check condition.
Oil Filter Renew Oil Filter.
Air Filter Renew Air Filter.
Interim Service – Every 4000 hours or 1 year (whichever is sooner)
Service Carry out Minor Service.
Separator Element Renew separator element.
Major Service – Every 8000 hours or 2 years (whichever is sooner)
Major Service Use correct Major Service Kit for model
Service Carry out Interim Service.
Minimum Pressure Valve Service valve.
Suction Regulator Service suction regulator.
Note: Renew the drive belt(s) every 16000 hours or 4 years, whichever is sooner.
2. MAINTENANCE SCHEDULE
Regular maintenance should be carried out by
your local CompAir BroomWade distributor as
detailed in the Maintenance Schedule. The
Schedule should be used as a general guide only.