User manual

page 55
Cyclon Series User Manual – Maintenance
11. Apply a film of clean oil to the seal of a new oil
filter element. Screw the element into the
housing until it contacts the gasket and
tighten a further
1
/3 turn.
12. Fill the separator to the correct level with
BroomWade approved lubricant, refit the filler
cap and tighten by hand.
13. Open the isolating valve to the user's system.
14. Run the compressor until it reaches working
temperature to ensure full circulation of the oil.
15. Check the oil level and top up as necessary.
Method (b)
1. Open the door to the service area.
2. Close the control air isolating valve, fitted to
the side of the manifold block (lever to the
vertical position) and the isolating valve in the
user's system.
3. Ensure that all pressure has been released
from the oil separator, remove the filler plug
and fit a suitable connector to the neck of the
filler pipe for the air supply.
4. Apply pressure to the compressor unit
(minimum of 4 bar or 60 psi).
5. Remove the plug and connect a hose
(minimum 10 mm bore) to the drain tap and
place the open end into a suitable container.
Risk of injury from hot oil under pressure.
6. Slowly open the drain tap and allow the oil to
drain into the container for disposal.
7. Close the drain tap, disconnect the hose and
remove the container. Refit the drain tap plug.
8. Close the air supply through the filler tube,
open the control air isolating valve (lever to
the horizontol position) and allow any
pressure to be released through the normal
blowdown process.
9. Remove the air supply and fitting from the
filler tube.
10. Remove and discard the old oil filter element.
11. Apply a film of clean oil to the seal of a new oil
filter element. Screw the element into the
housing until it contacts the gasket and
tighten a further
1
/3 turn.
12. Fill the separator to the correct level with
BroomWade approved lubricant, refit the filler
cap and tighten by hand.
13. Open the isolating valve to the user’s system.
14. Run the compressor until it reaches working
temperature to ensure full circulation of the oil.
15. Check the oil level and top up as necessary.
3.5 Drive Belt(s)
The drive belt tension is set at the factory and
requires no further attention.
When fitting a new belt adjust the tension
according to the instructions below. Run the
compressor for 30 minutes to allow the belt to
settle into the pulley grooves then stop the
compressor and re-tension the belt.
CAUTION: Any further tensioning will affect the life
of the belt.
1.5 mm
1
3
4
2
PI/97/035
DRIVE BELT ADJUSTMENT
WARNING
!
!