User manual

CompAir BroomWade Limited
page 62
Q101 MCB
R201 Temperature Sensor
S101 Emergency Stop Button
S201 Air Filter
T101 Control Transformer
Y101 Load Solenoid
Y102 Drain Solenoid Option
ELECTRICAL CONNECTIONS DIAGRAM
F1 Fused Terminal 1·6A
F2 Fused Terminal 3·15A
F101 Motor Overload Relay
KM101 Main Contactor
KM102 Star Contactor
KM103 Delta Contactor
M101 Drive Motor
P201 Pressure Sensor
DIGITAL INPUTS
123456789
X01
X14
ANALOG INPUTS
REMOTE CARD OPTION
(IF FITTED)
123456
X02
P201
21
-+
R201
ML1/9
ML1/7
ML1/10
ML1/8
210
211
212
213
204
200
201
202
ML1/11ML1/12
S101/2
S201
203
F101
T1
X2/1 X2/1 X2/1 X2/1 X2/1 X2/1 X2/1 X2/1 X2/1
(LK1)
X2/2
REMOTE LOAD ENABLE
REMOTE LOAD
REMOTE START ENABLE
REMOTE START
GROUP FAULT
REMOTE STOP
RELAY OUTPUTS
12
12 34 56 78
910
11 12
X03
X08
X1/1
X1/1
X1/1 X1/1 X1/1 X1/1 X1/1 X1/1
X1/4X1/3
109
S101/1
108
F2
3·15A
F1
1·6A
103
24V
104
105
106
0V
24V
0V
T101
REMOTE CARD
OPTION (IF FITTED)
575V
440/460V
415/380V
220/230V
0V
101
101
102
102
Q101
U
V
W
PE
KM101
F101
U1 V1 W1
U2 V2 W2
E
M101
3~
KM103
KM102
EARTH
BAR
X1/2 X1/2 X1/2X1/2X1/2X1/2X1/2X1/2X1/2
KM103
KM102
ML1/1
C105-222 DRAIN OPTION
KM101
106 109
121
116
KM102
KM103
Y101
ML1/2
ML1/3
Y102
ML1/4
110
111
113
115
112
114
107
X1/4 FITTED TO C330-C345 ONLY
ML1/3-ML1/4 C105-C222 ONLY
M101 Thermisters
C330-C345 ONLY
a
b
a
b
PI/97/052