Installation guide

5
P0902615 Issue 03 MICS-XC 4.1 Programming Record
Remote page
N
01
N
LinePool access
PRI-A
N
PRI-B
N
Pool A (9)
Y
Pool B ( )
N
Remote page
N
Rem line access
Show line:_
L001 Rem pkg
00
Change DN type
Show DN
637 Portable
Companion
Registration
Registration
N
Portable DNs
Show DN:
637
Availble
Radio data
Re-evaluation
Status:
Schedule:
Radios
Cell assignment
Show radio:
Unassigned
Antenna type
Show radio:
Internal
Cells
Show cell:_
Cell radios
Show radio:
Unassigned
Cell nghbrs
Show nghbr:
Unassigned
Cell rad nghbrs
ShowRadNghbr:
Unassigned
System LID:
Recd # length 3
DN length 3
Natnl length 10
BusName None
CbC limits
Pool PRI-A
Service: Public
Min in
Max in
Min out
Max out
Service: Tie
Service: FX
Service: OUTWATS
Service: 800
Pool PRI-B
Release reasons
Text:
None
Hospitality
Room/desk info
Show set:___
Room #: _
Adm pwd reqd:
Y
Call restrns
Vacant:
00
Use flt:__
Basic:
00
Mid:
00
Full:
00
Service time
Hour:
00
Minutes:
00
Alarm
Attn attempts:
3
Retry intrvl:
4
Attn duration:
15
Time format
12hr
Telco features
VMsg ctr tel#s
VMsg center 1
Tel#
No number
VMsg center 2
VMsg center 3
VMsg center 4
VMsg center 5
ONN blocking
Analog VSC
Tone None
Pulse None
BRI VSC
Code None
Software keys
(Used to activate Companion, ISDN PRI and
fixed access trunks/WAN access for Data
Modules)
SysID (8 digits)
Password keys
Key 1
(8 digits)
Key 2
(8 digits)
Key 3
(8 digits)
Hardware
Show Module:_
Cards on KSU
Cd1-KSU
Loop
Card type
Loop
Lines
Discon timer
460
(If T1 card)
Card type
T1
Lines
Discon timer
460
Answer timer
2
CO fail
T1A-547A
I/F levels
ISDN
Framing
ESF
Internal CSU
On
CSU line bld
0
DSX1 bld
000-100
Line coding
B8ZS
Clock Src
Primary
(If PRI card)
Card type:
PRI
Lines
(If more than one Protocol)
Protocol
NI-2
BchanSeq
Descend
CbC Routing
(If Protocol is DMS-100)
CbC values
FX
None
800
None
(If Protocol is NI-2)
CbC values
FX
None
800
None
(If Protocol is DMS-250)
CbC values
FX
None
800
None
900
None
(If Protocol is AT&T-4ESS)
CbC values
FX
None
800
None
I800
None
900
None
SDS
None
CO fail
TIA-547A
I/F levels:
ISDN
Framing
ESF
Internal CSU
On
CSU line bld
0
Line coding
B8ZS
Clock Src
Primary
(If DID card)
Card type
DID
Lines
(If E&M card)
Card type
E&M
Lines
Answer timer
2
(If BRI card)
Card type
Loops
Loop aaa
Type
T
Protocol
Sampling
Fixed
(For S and LT)
Assign DNs
Show DN:
_
Availabl
Loop DN:_
None
(For T & NT)
SPIDn
# of B-channls
1
Network DNs
DN1
Call type
Both
D-packet service
D-packet servc
LPnnn
None
TEIs
TEI
Clock Src
Primary
ONN blk
SuprsBit
DataMod settings Profile 1 only
(If DataMod=IDM 200)
Type
IDM 200
Fixed access
Show line:_
L001:
Unassigned
L001:
Channel:xx
DataMod NVRAM
(If DataMod=BayStack)
Type
BayStack
IP address
Fixed access
Show line:_
L001:
Unassigned
L001:
Channel:xx
Switched access
Line assignment
Show line:_
L001:
Unassigned
Dial-In:
None
LinePool access
LinePool PRI-A:
N
L001:
Unassigned
(If DataMod=SDI)
Type
SDI
Config
Ptl
V.35
DS0 rate
64k
TxClk src
Auto
TxClk invrsn
Off
Data invrsn
Off
Fixed access
Show line:_
L001:
Unassigned
L001:
Channel:xx
Lp state
None
Lpbk
Off
Cd2-KSU Loop
Mod 03 to 14 StnMod
Maintenance
System version
Port/DN status
Module status
Sys test log
Sys admin log