Installation guide

Page 100 of 206 Verifying a Meridian Companion installation
553-3601-220 Standard 4.00 November 1998
Figure 31: Floor plan with transcribed information
Note 1: The cell boundary value should be a high-power measurement. An
H
on the portable’s display indicates the portable is transmitting in
high-power mode (an
L
indicates low-power mode).
Note 2: RSSI measurements are displayed as negative values. The smaller
the negative value the stronger the signal strength. For example, a
signal strength of
-60
dBm is stronger than one of
-7 3
dBm.
If a significant area within the coverage area has an RSSI signal
strength less than the cell boundary value, refer to Meridian
Companion Site Planning Reference Manual to redeploy cell centers
in the impacted area to fill the gap, or add an additional cell center if
necessary.
Viewing radio and cell assignments
This procedure checks the integrity of the programming and should occur
immediately after reevaluation.
cell center
cell number
Base Station port number
02
0106,
0113
14
0115,
0122
09
0104,
0118
36
0127,
0131
57
0102,
0109
35
0124,
0129
64
0107,
0120