Installation guide

Troubleshooting and maintenance 5-13
Installation and Maintenance Standard 3.0 March 1994
c. Ensure that the DVP Cards and the C25 Cards are firmly connect-
ed.
3 Test the DVP and C25 Cards as follows:
a. From the Meridian Mail login screen, press W.
You are presented with a small pop-up menu.
b. If you can’t see the cursor on this menu, press I.
c. Press and to move the cursor to “Console”
and S to select it.
The terminal displays the results of the Meridian Mail diagnostics.
Note:
Card 4 is the DVP Card in slot MM2.
Card 5 is the first C25 Card attached to the DVP Card in slot MM2.
Card 6 is the second C25 Card attached to the DVP Card in slot MM2.
Card 7 is the DVP Card in slot 9.
Card 8 is the first C25 Card attached to the DVP Card in slot 9.
Card 9 is the second C25 Card attached to the DVP Card in slot 9.
d. Press W and select “MMI” to return to the Meridian Mail
logon screen.
e. Replace any cards that have not passed the diagnostics.
f. In order to bring them back into service, you must run Out of Service
Diagnostics on each of the cards you replace, as follows:
i. Log on to Meridian Mail.
ii. From the Main Menu, choose
“5 System Status and Maintenance”“2 Card Status”.
iii. Press
and at the prompt enter the number of each
card that you replaced.
iv. Press
and enter the card numbers.
v. Press
and enter the card numbers.
g. You must also enable the new hardware locations, as follows:
i. From the Card Status form, press
.
ii. From the System Status and Maintenance Menu, choose “3
Channel Status”.