Specifications
8/20q Fibre Channel Switch installation and reference guide 13
Maintenance button
The Maintenance button (Figure 2) is a dual-function momentary switch on the front panel. Its purpose is to 
reset the switch or to place the switch in maintenance mode. Maintenance mode sets the IP address to 
10.0.0.1 and provides access to the switch for maintenance purposes when flash memory or the resident 
configuration file is corrupted. For more information, see ”Recovering a switch using maintenance mode” 
on page 46.
Resetting a switch
To reset the switch, press and hold the Maintenance button with a pointed tool for less than 2 seconds. The 
switch will respond as follows:
1. All the switch LEDs will illuminate except the System Fault LED.
2. After approximately 1 minute, the power-on self test (POST) begins, extinguishing the Heartbeat LED.
3. When the POST is complete, the Input Power LED is illuminated and the Heartbeat LED is flashing once 
per second.
Placing the switch in maintenance mode
To place the switch in maintenance mode:
1. Isolate the switch from the fabric.
2. Press and hold the Maintenance button with a pointed tool for a few seconds until only the Heartbeat 
LED (Figure 2) is illuminated. Continue holding the maintenance button until the Heartbeat LED goes 
off, then release the button. The Heartbeat LED illuminates continuously while the switch is in 
maintenance mode.
To exit maintenance mode and return to normal operation, press and release the Maintenance button 
momentarily to reset the switch.