External RAID Controller & Subsystem Operation Manual

Table Of Contents
Terminal Operation
7-26
Viewing and Editing SCSI IDs - Host Channel
Choose a host channel, then press [ENTER]. Choose “View and Edit
SCSI ID.” A list of existing ID(s) will be displayed on the screen.
You may then choose to add or delete an existing ID.
Viewing and Editing SCSI IDs
Adding a SCSI ID (Primary/Secondary Controller ID)
In single controller mode, you should set the Secondary Controller’s
ID to “NA”. In dual-controller mode, you need to set an ID for the
Secondary controller on each of your drive channels.
Press [ENTER] on one of the existing IDs. Choose “Add Channel
SCSI ID,” then choose to assign an ID for either the “Primary
Controller” or "Secondary Controller." A list of SCSI IDs will
appear. Choose a SCSI ID. DO NOT choose a SCSI ID used by
another device on the same channel. The defaults are PID=8 and
SID=9 (SCSI channel). In redundant mode, logical drives mapped to
a primary ID will be managed by the primary controller, and vice
versa.