External RAID Controller & Subsystem Operation Manual

Table Of Contents
Advanced Configurations
9-8
6. Choose “Predictable Failure Test,” the controller will force the
drive to simulate predictable drive errors.
7. Press [ENTER], and after a while (the next time the controller
performs “Periodic Drive Check”), the controller will detect the
errors simulated by the drive. An error message displays like this:
“[1142] SMART-CH:? ID:? Predictable Failure Detected (TEST).” If
this error message appears, it means your drive supports S.M.A.R.T.
features.
8. Otherwise, you may simply refer to related documentation or
contact drive manufacturer for information about whether the drive
model and drive firmware version support S.M.A.R.T..
Using S.M.A.R.T. Functions
1. Enable “SMART” on the RAID controller.
2. Make sure your drives do support S.M.A.R.T. so that your
system will work fitly.
3. The “Detect Only” Setting:
3a. In \View and Edit Configuration Parameters\Drive-side SCSI
Parameters\Drive Predictable Failure Mode <SMART>, choose
“Detect Only.”