HSUTIL cannot install firmware on devices that have been configured as single
disk drive units or as members of a storageset, spareset, or failedset. If you want
to install firmware on a device that has previously been configured as a single
disk drive, delete the unit number and storageset name associated with it.
During the installation, the source disk drive is not available for other subsystem
operations.
Some devices may not reflect the new firmware version number when viewed
from the “other” controller in a dual-redundant configuration. If you experience
this, enter the following CLI command: CLEAR_ERRORS device-name
UNKNOWN.
Do not issue any CLI commands that access or inspect devices that are being
formatted.
Use the following steps to upgrade firmware with HSUTIL:
1. Connect a PC or terminal to the maintenance port on the controller that accesses
the device you want to upgrade.
2. Configure a single-disk unit.
NOTE: In the next steps, you’ll copy the firmware image to this unit, then use
HSUTIL to distribute it to the devices you’re upgrading. This unit must be a newly
initialized disk with no label or file structure to ensure that the firmware image
resides in contiguous blocks starting from LBN 0 or another known LBN.
Additionally, write-back caching must be disabled (see
HSZ80 ACS Version 8.3
Configuration and CLI Reference Guide
).
3. Copy the firmware image to the single-disk unit that you configured in step 2.
The firmware image must begin at a known LBN—usually 0—and must be
contiguous. See the documentation that accompanied your hosts operating
system for instructions on copying firmware images to a disk drive.
CAUTION: You must quiesce the host load before running HSUTIL or
damage to the storage device can occur.
4. Start HSUTIL with the following command:
RUN HSUTIL