Technical data

4–32 Troubleshooting
In addition, information related to the solid OCP patterns may be displayed on the
maintenance terminal using %FLL formatting, as detailed in the following examples:
■❍❍❍❍❍❍
0 No program card detected or kill
asserted by other controller.
Controller unable to read program
card.
Ensure that program card is properly
seated while resetting the controller.
If the error persists, try the card with
another controller; or replace the
card. Otherwise, replace the
controller that reported the error.
❏❍❍❍❍❍❍
0 Catastrophic controller or power
failure.
Check power. If good, reset
controller. If problem persists, reseat
controller module and reset
controller. If problem is still evident,
replace controller module.
Table 4–5 Solid OCP Patterns (Continued)
Pattern OCP
Code
Error Repair Action
%FLL--HSZ> --13-JAN-1946 04:39:45 (time not set)-- OCP Code: 38
Controller operation terminated.
%FLL--HSZ> --13-JAN-1946 04:32:26 (time not set)-- OCP Code: 26
Memory module is missing.