Technical data
4–40 Troubleshooting
The following example shows the FMU translation of a last-failure code.
FMU>DESCRIBE LAST_FAILURE_CODE 206C0020
Last Failure Code: 206C0020
Description: Controller was forced to restart in order for new controller
code image to take effect.
Reporting Component: 32.(20)
Description: Command Line Interpreter
Reporting component’s event number: 108.(6C)
Restart Type: 2.(02)
Description: Automatic hardware restart
Instance Codes and Last-Failure Codes
Instance codes identify and accompany significant events that do not cause the
controller to terminate operation; last-failure codes identify and accompany failure
events that cause the controller to stop operating. Last-failure codes are sent to the
host only after the affected controller is restarted successfully.
Controlling the Display of Significant Events and
Failures
You can control how the fault-management software displays significant events and
failures with FMU’s SET command.