Technical data
5–22 Event Reporting: Templates and Codes
Table 5–1 Instance Codes
Instance Code Description Template
01010302 An unrecoverable hardware detected fault occurred. 01
0102030A An unrecoverable software inconsistency was detected or an intentional
restart or shutdown of controller operation was requested.
01
01032002 Nonvolatile parameter memory component EDC check failed; content of
the component reset to default settings.
11
02020064 Disk Bad Block Replacement attempt completed for a write within the
user data area of the disk. Note that due to the way Bad Block
Replacement is performed on SCSI disk drives, information on the actual
replacement blocks is not available to the controller and is therefore not
included in the event report.
51
02032001 Journal SRAM backup battery failure; detected during system restart.
The Memory Address field contains the starting physical address of the
Journal SRAM.
12
02042001 Journal SRAM backup battery failure; detected during periodic check.
The Memory Address field contains the starting physical address of the
Journal SRAM.
12
02052301 A processor interrupt was generated by the CACHEA0 Memory Controller
with an indication that the CACHE backup battery has failed or is low
(needs charging). The Memory Address field contains the starting
physical address of the CACHEA0 memory.
12
02072201 The CACHEA0 Memory Controller failed testing performed by the Cache
Diagnostics. The Memory Address field contains the starting physical
address of the CACHEA0 memory.
14
02082201 The CACHEA1 Memory Controller failed testing performed by the Cache
Diagnostics. The Memory Address field contains the starting physical
address of the CACHEA1 memory.
14