02745A0A The device specified in the Device Locator field had a read error.
Attempts to repair the error with data from another mirrorset member
failed due to lack of alternate error-free data source.
51
02755601 The device specified in the Device Locator field had a read error.
Attempts to repair the error with data from another mirrorset member
failed due to a write error on the original device. The original device will
be removed from the mirrorset.
51
02773D01 The mirrored cache is not being used because the data in the mirrored
cache is inconsistent with the data in the primary cache. The primary
cache contains valid data, so the controller is caching solely from the
primary cache. The mirrored cache is declared “failed”, but this is not
due to a hardware fault, only inconsistent data. Mirrored writes have
been disabled until this condition is cleared. NOte that in this instance
the Memory Address, Byte Count, FX Chip register, Memory Controller
register, and Diagnostic register fields are undefined.
14
02782301 The cache backup battery is not present. The Memory Address field
contains the starting physical address of the CACHEA0 memory.
12
02792301 The cache backup battery covering the mirror cache is not present. The
Memory Address field contains the starting physical address of the
CACHEB1 memory.
12
027A2201 The CACHEB0 Memory Controller failed Cache Diagnostics testing
performed on the other cache during a cache failover attempt. The
Memory Address field contains the starting physical address of the
CACHEB0 memory.
14
027B2201 The CACHEB1 Memory Controller failed Cache Diagnostics testing
performed on the other cache during a cache failover attempt. The
Memory Address field contains the starting physical address of the
CACHEB1 memory.
14