Technical data

5–32 Event Reporting: Templates and Codes
027C2201 The CACHEB0 and CACHEB1 Memory Controllers failed Cache
Diagnostics testing performed on the other cache during a cache
failover attempt. The Memory Address field contains the starting
physical address of the CACHEB0 memory.
14
027D5B01 The Mirrorset associated with the logical unit has gone inoperative due
to a disaster tolerance failsafe locked condition.
51
027E5B01 The command failed because the disaster tolerance mirrorset went
failsafe locked prior to command completion. The Information field of
the Device Sense Data contains the block number of the first block in
error.
51
027F2301 The CACHE backup battery has been declared bad. The battery did not
become fully charged within the expected duration. The Memory
Address field contains the starting physical address of the CACHEA0
memory.
12
02805B01 The command failed because the disaster tolerance mirrorset is failsafe
locked. The Information field of the Device Sense Data contains the
block number of the first block in error.
51
02815B01 The command failed because the disaster tolerance mirrorset is failsafe
locked. The Information field of the Device Sense Data contains the
block number of the first block in error.
51
02825C64 The Mirrorset associated with the logical unit has just had a
membership change such that disaster tolerance failsafe error mode
can now be enabled if desired.
51
02864002 The controller has set the specified unit DATA Safety Write Protected due
to an unrecoverable device failure which prevents writing cached data.
51
Table 5–1 Instance Codes (Continued)
Instance Code Description Template