Technical data
5–37
Compaq HSZ80 Array Controller ACS Version 8.3 Maintenance and Service Guide
03BE0701 The EMU for the cabinet indicated by the Associated Port field has
powered down the cabinet because there are less than four working
power supplies present. Note that in this instance the Associated Target,
Associated Additional Sense Code, and Associated Additional Sense
Code Qualifier fields are undefined.
41
03C00601 The EMU for the cabinet indicated by the Associated Port field has
powered down the cab because a fan has been missing for more than
eight minutes. Note that in this instance the Associated Target,
Associated Additional Sense Code, and Associated Additional Sense
Code Qualifier fields are undefined.
41
03C80101 No command control structures available for operation to a device which
is unknown to the controller. Note that in this instance the Associated
Additional Sense Code and Associated Additional Sense Code Qualifier
fields are undefined.
41
03C92002 SCSI interface chip command timeout during operation to a device
which is unknown to the controller. Note that in this instance the
Associated Additional Sense Code and Associated Additional Sense
Code Qualifier fields are undefined.
41
03CA4002 Byte transfer timeout during operation to a device which is unknown to
the controller. Note that in this instance the Associated Additional Sense
Code and Associated Additional Sense Code Qualifier fields are
undefined.
41
03CB0101 Miscellaneous SCSI Port Driver coding error detected during operation to
a device which is unknown to the controller. Note that in this instance
the Associated Additional Sense Code and Associated Additional Sense
Code Qualifier fields are undefined.
41
Table 5–1 Instance Codes (Continued)
Instance Code Description Template