Technical data

5–38 Event Reporting: Templates and Codes
03CC0101 An error code was reported which was unknown to the Fault
Management software. Note that in this instance the Associated
Additional Sense Code and Associated Additional Sense Code Qualifier
fields are undefined.
41
03CD2002 Device port SCSI chip reported gross error during operation to a device
which is unknown to the controller. Note that in this instance the
Associated Additional Sense Code and Associated Additional Sense
Code Qualifier fields are undefined.
41
03CE2002 Non-SCSI bus parity error during operation to a device which is
unknown to the controller. Note that in this instance the Associated
Additional Sense Code and Associated Additional Sense Code Qualifier
fields are undefined.
41
03CF0101 Source driver programming error encountered during operation to a
device which is unknown to the controller. Note that in this instance the
Associated Additional Sense Code and Associated Additional Sense
Code Qualifier fields are undefined.
41
03D04002 A failure occurred while attempting a SCSI Test Unit Ready or Read
Capacity command to a device. The device type is unknown to the
controller. Note that in this instance the Associated Additional Sense
Code and Associated Additional Sense Code Qualifier fields are
undefined.
41
03D14002 The identification of a device does not match the configuration
information. The actual device type is unknown to the controller. Note
that in this instance the Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.
41
Table 5–1 Instance Codes (Continued)
Instance Code Description Template