Technical data
5–41
Compaq HSZ80 Array Controller ACS Version 8.3 Maintenance and Service Guide
03DE450A During device initialization, the device reported the SCSI Sense Key
ABORTED COMMAND. This indicates the target aborted the command.
The initiator may be able to recover by trying the command again.
41
03DF450A During device initialization, the device reported the SCSI Sense Key
EQUAL. This indicates a SEARCH DATA command has satisfied an equal
comparison.
41
03E0450A During device initialization, the device reported the SCSI Sense Key
VOLUME OVERFLOW. This indicates a buffered peripheral device has
reached the end-of-partition and data may remain in the buffer that has
not been written to the medium. A RECOVER BUFFERED DATA
command(s) may be issued to read the unwritten data from the buffer.
41
03E1450A During device initialization, the device reported the SCSI Sense Key
MISCOMPARE. This indicates the source data did not match the data
read from the medium.
41
03E2450A During device initialization, the device reported a reserved SCSI Sense
Key.
41
03EE0064 The EMU for the cabinet indicated by the Associated Port field has
become available. Note that the Associated Target, Associated
Additional Sense Code, and the Associated Additional Sense Code
Qualifier fields are undefined.
41
03EF8301 The EMU for the cabinet indicated by the Associated Port field has
become unavailable. Note that the Associated Target, Associated
Additional Sense Code, and the Associated Additional Sense Code
Qualifier fields are undefined.
41
Table 5–1 Instance Codes (Continued)
Instance Code Description Template