Technical data

5–42 Event Reporting: Templates and Codes
03F10502 The SWAP interrupt from the device port indicated by the Associated
Port field can not be cleared. All SWAP interrupts from all ports will be
disabled until corrective action is taken. When SWAP interrupts are
disabled, both controller front panel button presses and removal/
insertion of devices are not detected by the controller. Note that in this
instance the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.
41
03F20064 The SWAP interrupts have been cleared and re-enabled for all device
ports. Note that in this instance the Associated Port, Associated Target,
Associated Additional Sense Code, and Associated Additional Sense
Code Qualifier fields are undefined.
41
03F30064 An asynchronous SWAP interrupt was detected by the controller for the
device port indicated by the Associated Port field. Possible reasons for
this occurrence include:
device insertion or removal.
shelf power failure.
SWAP interrupts reenabled.
Note that in this instance the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41
03F40064 Device services had to reset the port to clear a bad condition. Note that
in this instance the Associated Target, Associated Additional Sense
Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41
Table 5–1 Instance Codes (Continued)
Instance Code Description Template