Technical data

5–43
Compaq HSZ80 Array Controller ACS Version 8.3 Maintenance and Service Guide
03F60402 The controller shelf is reporting a problem. This could mean one or both
of the following:
If the shelf is using dual power supplies, one power supply has failed.
One of the shelf cooling fans has failed.
Note that in this instance the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41
03F70401 The shelf indicated by the Associated Port field is reporting a problem.
This could mean one or both of the following:
If the shelf is using dual power supplies, one power supply has failed.
One of the shelf cooling fans has failed.
Note that in this instance the Associated Target, Associated Additional
Sense Code, and Associated Additional Sense Code Qualifier fields are
undefined.
41
03F80701 The EMU has detected one or more bad power supplies. Note that in this
instance the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.
41
03F90601 The EMU has detected one or more bad fans. Note that in this instance
the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.
41
03FA0D01 The EMU has detected an elevated temperature condition. Note that in
this instance the Associated Target, Associated Additional Sense Code,
and Associated Additional Sense Code Qualifier fields are undefined.
41
03FB0E01 The EMU has detected an external air sense fault. Note that in this
instance the Associated Target, Associated Additional Sense Code, and
Associated Additional Sense Code Qualifier fields are undefined.
41
Table 5–1 Instance Codes (Continued)
Instance Code Description Template