07050064 Failover Control received a Last Gasp message from the other controller.
The other controller is expected to restart itself within a given time
period. If it does not, it will be held reset with the “Kill” line.
05
07060C01 Failover Control detected that both controllers are acting as SCSI ID 6.
Since ids are determined by hardware, it is unknown which controller is
the real SCSI ID 6. Note that in this instance the Last Failure Code and
Last Failure Parameters fields are undefined.
05
07070C01 Failover Control detected that both controllers are acting as SCSI ID 7.
Since ids are determined by hardware, it is unknown which controller is
the real SCSI ID 7. Note that in this instance the Last Failure Code and
Last Failure Parameters fields are undefined.
05
07080B0A Failover Control was unable to send keepalive communication to the
other controller. It is assumed that the other controller is hung or not
started. Note that in this instance the Last Failure Code and Last Failure
Parameters fields are undefined.
05
0C00370A Memory System Error Analysis is indicated in the information preserved
during a previous last failure but no error conditions are indicated in the
available Memory Controller registers. The Quadrant 0 Memory
Controller (CACHEA0) registers content is supplied.
14
0C103E02 The Quadrant 0 Memory Controller (CACHEA0) detected an Address
Parity error.
14
0C113E02 The Quadrant 1 Memory Controller (CACHEA1) detected an Address
Parity error.
14
0C123E02 The Quadrant 2 Memory Controller (CACHEB0) detected an Address
Parity error.
14
0C133E02 The Quadrant 3 Memory Controller (CACHEB1) detected an Address
Parity error.