Technical data

5–50 Event Reporting: Templates and Codes
Repair Action
The Repair Action found at byte offset 105 indicates the recommended repair action
code assigned to the event. This value is used during Symptom-Directed Diagnosis
procedures to determine what notification/recovery action should be taken. For more
details, see “Recommended Repair Action Codes,” page 5–95.
Error Numbers
Located at byte offset 106, the Error Number, when combined with the value
contained in the Component ID field, uniquely-identifies the condition detected.
Component IDs
A component ID uniquely identifies the software component that detected the event
and is found at byte offset {11}35 (see “Component Identifier Codes,” page 5–101).
Table 5–3 contains the last failure codes that can be issued by the controller’s fault-
management software.
Table 5–3 Last Failure Codes
Code Description
01000100 Memory allocation failure during executive initialization.
01010100 An interrupt without any handler was triggered.
01020100 Entry on timer queue was not of type AQ or BQ.
01030100 Memory allocation for a facility lock failed.
01040100 Memory initialization called with invalid memory type.