Technical data
5–54 Event Reporting: Templates and Codes
011C0011 Controller execution terminated via display of solid fault code in OCP LEDs. Note that upon
receipt of this Last Failure in a last gasp message the other controller in a dual controller
configuration will inhibit assertion of the KILL line.
■ Last Failure Parameter [0] contains the OCP LED solid fault code value.
011D0100 Relocated zero (for example, C0000000) entered cia call or branch.
018000A0 A powerfail interrupt occurred.
018600A0 A processor interrupt was generated with an indication that the other controller in a dual
controller configuration asserted the KILL line to disable this controller.
018700A0 A processor interrupt was generated with an indication that the (//) RESET button on the
controller module was depressed.
018800A0 A processor interrupt was generated with an indication that the program card was removed.
018900A0 A processor interrupt was generated with an indication that the controller inactivity watch dog
timer expired.
018F2087 A NMI interrupt was generated with an indication that a controller system problem occurred.
■ Last Failure Parameter [0] contains the value of read diagnostic register 0.
■ Last Failure Parameter [1] contains the value of read diagnostic register 1.
■ Last Failure Parameter [2] contains PCI status. Bits 31:24 hold PCFX PSCR status and bits
15:08 hold PLX PSCR status.
■ Last Failure Parameter [3] contains the PCFX PDAL control/status register.
■ Last Failure Parameter [4] contains the IBUS address of error register.
■ Last Failure Parameter [5] contains the previous PDAL address of error register.
■ Last Failure Parameter [6] contains the current PDAL address of error register.
Table 5–3 Last Failure Codes (Continued)
Code Description