Technical data
5–58 Event Reporting: Templates and Codes
01982087 The Ibus encountered a parity error.
■ Last Failure Parameter [0] contains the value of read diagnostic register 0.
■ Last Failure Parameter [1] contains the value of read diagnostic register 1.
■ Last Failure Parameter [2] contains the value of read diagnostic register 2.
■ Last Failure Parameter [3] contains he value of write diagnostic register 0.
■ Last Failure Parameter [4] contains the value of write diagnostic register 1.
■ Last Failure Parameter [5] contains the IBUS address of error register.
■ Last Failure Parameter [6] contains the RIP.
01992088 An error was detected by the PLX.
■ Last Failure Parameter [0] contains the value of read diagnostic register 0.
■ Last Failure Parameter [1] contains the value of read diagnostic register 1.
■ Last Failure Parameter [2] contains the value of write diagnostic register 0.
■ Last Failure Parameter [3] contains the value of write diagnostic register 1.
■ Last Failure Parameter [4] contains the IBUS address of error register.
■ Last Failure Parameter [5] contains the PLX status register.
■ Last Failure Parameter [6] contains the previous PDAL address of error register.
■ Last Failure Parameter [7] contains the RIP.
02010100 Initialization code was unable to allocate enough memory to set up the send data descriptors.
02040100 Unable to allocate memory necessary for data buffers.
02050100 Unable to allocate memory for the Free Buffer Array.
02080100 A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory when populating the disk
read DWD stack.
02090100 A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory when
populating the disk write DWD stack.
Table 5–3 Last Failure Codes (Continued)
Code Description