Technical data

5–70 Event Reporting: Templates and Codes
03290100 The required Event Information Packet (EIP) or Device Work Descriptor (DWD) were not
supplied to the Device Services error logging code.
032B0100 A Device Work Descriptor (DWD) was supplied with a NULL Physical Unit Block (PUB) pointer.
03320101 An invalid code was passed to the error recovery thread in the error_stat field of the PCB.
Last Failure Parameter[0] contains the PCB error_stat code.
03330188 A parity error was detected by a device port while sending data out onto the SCSI bus.
Last Failure Parameter [0] contains the PCB port_ptr value.
Last Failure Parameter [1] contains the PCB copy of the device port TEMP register.
Last Failure Parameter [2] contains the PCB copy of the device port DBC register.
Last Failure Parameter [3] contains the PCB copy of the device port DNAD register.
Last Failure Parameter [4] contains the PCB copy of the device port DSP register.
Last Failure Parameter [5] contains the PCB copy of the device port DSPS register.
Last Failure Parameter [6] contains the PCB copies of the device port SSTAT2/SSTAT1/
SSTAT0/DSTAT registers.
Last Failure Parameter [7] contains the PCB copies of the device port LCRC/RESERVED/
ISTAT/DFIFO registers.
Table 5–3 Last Failure Codes (Continued)
Code Description