Technical data
5–74 Event Reporting: Templates and Codes
03450188 A Master Data Parity Error was detected by a port.
■ Last Failure Parameter [0] contains the PCB port_ptr value.
■ Last Failure Parameter [1] contains the PCB copies of the device port DCMD/DBC
registers.
■ Last Failure Parameter [2] contains the PCB copy of the device port DNAD register.
■ Last Failure Parameter [3] contains the PCB copy of the device port DSP register.
■ Last Failure Parameter [4] contains the PCB copy of the device port DSPS register.
■ Last Failure Parameter [5] contains the PCB copies of the device port DSTAT/SSTAT0/
SSTAT1/SSTAT2 registers.
■ Last Failure Parameter [6] contains the PCB copies of the device port DFIFO/ISTAT/SBCL/
RESERVED registers.
■ Last Failure Parameter [7] contains the PCB copies of the device port SIST0/SIST1/SXFER/
SCNTL3 registers.
03470100 Insufficient memory available for target block allocation.
03480100 Insufficient memory available for device port info block allocation.
03490100 Insufficient memory available for autoconfig buffer allocation.
034A0100 Insufficient memory available for PUB allocation.
034B0100 Insufficient memory available for DS init buffer allocation.
034C0100 Insufficient memory available for static structure allocation.
034D0100 DS init DWDs exhausted.
034E2080 Diagnostics report all device ports are broken.
034F0100 Insufficient memory available for reselect target block allocation.
03500100 Insufficient memory available for command disk allocation.
03520100 A failure resulted when an attempt was made to allocate a DWD for use by DS CDI.
035A0100 Invalid SCSI message byte passed to DS.
Table 5–3 Last Failure Codes (Continued)
Code Description