Technical data
5–76 Event Reporting: Templates and Codes
03A08093 A configuration or hardware error was reported by the EMU.
■ Last Failure Parameter [0] contains the solid OCP pattern which identifies the type of
problem encountered.
■ Last Failure Parameter [1] contains the cabinet ID reporting the problem.
■ Last Failure Parameter [2] contains the SCSI Port number where the problem exists (if
port-specific).
03A28193 The EMU reported Terminator Power out of range.
■ Last Failure Parameter [0] contains a bit mask indicating which SCSI Port numbers where
the problem exists for cab 0. Bit 0 set indicates SCSI Port 1, Bit 1 set indicates SCSI port 2,
etc.
■ Last Failure Parameter [1] contains a bit mask indicating which SCSI Port numbers where
the problem exists for cab 2.
■ Last Failure Parameter [2] contains a bit mask indicating which SCSI Port numbers where
the problem exists for cab 3.
03A30790 The EMU in cab 0 is performing an emergency shutdown because there are less than four
functioning power supplies.
03A40D90 The EMU in cab 0 is performing an emergency shutdown because it has determined that the
temperature is above the maximum limit.
03A50690 The EMU in cab 0 is performing an emergency shutdown because a fan has been missing for
more than eight minutes.
04010101 The requester id component of the instance code passed to FM$REPORT_EVENT is larger than
the maximum allowed for this environment.
■ Last Failure Parameter[0] contains the instance code value.
Table 5–3 Last Failure Codes (Continued)
Code Description