Technical data
5–79
Compaq HSZ80 Array Controller ACS Version 8.3 Maintenance and Service Guide
07030100 Unable to start the Failover Control Timer before main loop.
07040100 Unable to restart the Failover Control Timer.
07050100 Unable to allocate flush buffer.
07060100 Unable to allocate active receive fcb.
07070100 The other controller killed this, but could not assert the kill line because nindy on or in debug.
So it killed this now.
07080000 The other controller crashed, so this one must crash too.
07090100 A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory when allocating VA Request
Items.
08010101 A remote state change was received from the FOC thread that NVFOC does not recognize.
■ Last Failure Parameter[0] contains the unrecognized state value.
08020100 No memory could be allocated for a NVFOC information packet.
08030101 Work received on the S_nvfoc_bque did not have a NVFOC work id.
■ Last Failure Parameter[0] contains the id type value that was received on the NVFOC work
queue.
08040101 Unknown work value received by the S_nvfoc_bque.
■ Last Failure Parameter[0] contains the unknown work value.
08060100 A really write command was received when the NV memory was not locked.
08070100 A write to NV memory was received while not locked.
08080000 The other controller requested this controller to restart.
08090010 The other controller requested this controller to shutdown.
080A0000 The other controller requested this controller to selftest.
080B0100 Could not get enough memory to build a FCB to send to the remote routines on the other
controller.
080C0100 Could not get enough memory for FCBs to receive information from the other controller.
Table 5–3 Last Failure Codes (Continued)
Code Description