Technical data
5–84 Event Reporting: Templates and Codes
0A320102 ILF$LOG_ENTRY, page guard check failed.
■ Last Failure Parameter [0] contains the DWD address value.
■ Last Failure Parameter [1] contains the buffer address value.
0A330100 ilf_output_error, message_keeper_array full.
0A340101 ilf_output_error, no memory for message display.
0A350100 DWD failed validation.
0B010010 Due to an operator request, the controllers non-volatile configuration information has been
reset to its initial state.
0B020100 The controller has insufficient free memory to allocate a Configuration Manager work item
needed to perform the requested configuration reset.
0B030100 The controller has insufficient free memory to allocate a Configuration Manager work item
needed to perform the requested configuration restore.
0B040100 The controller has insufficient free memory to allocate a Configuration Manager WWL work
item needed to perform the requested World-Wide LUN ID change.
0B050100 More requests to WWL$NOTIFY have been made than can be supported.
0B060100 A call to WWL$UPDATE resulted in the need for another World-Wide LUN ID slot, and no free
slots were available.
0D000011 The EMU firmware returned a bad status when told to poweroff. Last Failure Parameter [0]
contains the value of the bad status.
12000103 Two values found not equal.
■ Last Failure Parameter [0] contains the ASSUME instance address.
■ Last Failure Parameter [1] contains first variable value.
■ Last Failure Parameter [2] contains second variable value.
Table 5–3 Last Failure Codes (Continued)
Code Description