5–98 Event Reporting: Templates and Codes
3D Either the primary cache or the mirrored cache has inconsistent data. Check for the
following conditions to determine appropriate means to restore mirrored copies.
If the mirrored cache is reported as inconsistent and a previous FRU Utility warmswap
of the mirrored cache module was unsuccessful, retry the procedure via the FRU Utility,
by removing the module and re-inserting the same or a new module.
Otherwise, enter the CLI command SHUTDOWN THIS to clear the inconsistency upon
reboot.
3E Replace the indicated cache module.
3F No action necessary, cache diagnostics will determine whether the indicated cache module
is faulty.
40 If the Sense Data FRU field is non-zero, follow repair action 41. Otherwise, replace the
appropriate FRU associated with the device’s SCSI interface or the entire device.
41 Consult the devices maintenance manual for guidance on replacing the indicated device
FRU.
43 Update the configuration data to correct the problem.
44 Replace the SCSI cable for the failing SCSI bus. If the problem persists, replace the controller
backplane, drive backplane, or controller module.
45 Interpreting the device supplied Sense Data is beyond the scope of the controller’s firmware.
See the device’s service manual to determine the appropriate repair action, if any.
50 The RAIDset is inoperative for one or more of the following reasons:
More than one member malfunctioned. Perform repair action 55.
More than one member is missing. Perform repair action 58.
Before reconstruction of a previously replaced member completes another member
becomes missing or malfunctions. Perform repair action 59.
The members have been moved around and the consistency checks show mismatched
members. Perform repair action 58.
Table 5–4 Recommended Repair Action Codes (Continued)
Code Description