Technical data

5–99
Compaq HSZ80 Array Controller ACS Version 8.3 Maintenance and Service Guide
51 The mirrorset is inoperative for one or more of the following reasons:
The last NORMAL member has malfunctioned. Perform repair actions 55 and 59.
The last NORMAL member is missing. Perform repair action 58.
The members have been moved around and the consistency checks show mismatched
members. Perform repair action 58.
52 The indicated Storageset member was removed for one of the following reasons:
The member malfunctioned. Perform repair action 56.
By operator command. Perform repair action 57.
53 The STORAGESET may be in a state that prevents the adding of a replacement member,
check the state of the STORAGESET and its associated UNIT and resolve the problems found
before adding the replacement member.
54 The device may be in a state that prevents adding it as a replacement member or may not be
large enough for the STORAGESET. Use another device for the ADD action and perform repair
action 57 for the device that failed to be added.
55 Perform the repair actions indicated in any and all event reports found for the devices that
are members of the STORAGESET.
56 Perform the repair actions indicated in any and all event reports found for the member
device that was removed from the STORAGESET. Then perform repair action 57.
57 Delete the device from the FAILEDSET and redeploy, perhaps by adding it to the SPARESET so
it will be available to be used to replace another failing device.
58 Install the physical devices that are members of the STORAGESET in the proper Port, Target,
and LUN locations.
59 Delete the STORAGESET, recreate it with the appropriate ADD, INITIALIZE, and ADD UNIT
commands and reload its contents from backup storage.
5A Restore the MIRRORSET data from backup storage.
Table 5–4 Recommended Repair Action Codes (Continued)
Code Description