Technical data

5–100 Event Reporting: Templates and Codes
5B The mirrorset is inoperative due to a disaster tolerance failsafe locked condition, as a result
of the loss of all local or remote NORMAL/NORMALIZING members while
ERROR_MODE=FAILSAFE was enabled. To clear the failsafe locked condition, enter the CLI
command SET unit-number ERROR_MODE=NORMAL.
5C The mirrorset has at least one local NORMAL/NORMALIZING member and one remote
NORMAL/NORMALIZING member. Failsafe error mode can now be enabled by entering the CLI
command SET unit-number ERROR_MODE=FAILSAFE.
80 An EMU fault has occurred.
81 The EMU reported terminator power out of range. Replace the indicated I/O module(s).
83 An EMU (Environmental Monitoring Unit) has become unavailable.
This EMU Unit (and associated cabinet) may have been removed from the subsystem; no
action is required.
The cabinet has lost power; restore power to the cabinet.
The EM- to-EMU communications bus cable has been disconnected or broken; replace
or reconnect the cable to reestablish communications.
The specified EMU is broken; replace the EMU module.
The EMU in cabinet 0 is broken; replace the EMU module.