Technical data

2–22
Replacement Procedures
7. Enter option 2, Install a controller or cache module, from the FRUTIL Main
menu. FRUTIL displays the Install Options menu:
Install Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
Enter choice: 1, 2, 3, or 4 ->
8. Enter option 1, Other controller and cache module, from the Install Options
menu. FRUTIL display the following:
Insert both the slot A [
or B
] controller and cache module? Y/N
9. Enter Y(es) and press return. FRUTIL displays the following:
Quiescing all device ports. Please wait...
Device Port 1 quiesced.
Device Port 2 quiesced.
Device Port 3 quiesced.
Device Port 4 quiesced.
Device Port 5 quiesced.
Device Port 6 quiesced.
All device ports quiesced.
.
.
.
Perform the following steps:
1. Turn off the battery for the new cache module by pressing
the battery’s shut off button for five seconds
2. Connect the battery to the new cache module.
3. Insert the new cache module in slot A [
or B
] within 4
minutes.
NOTE: A countdown timer allows a total of four minutes to install both the cache
module and controller. If you exceed four minutes, “this controller” will exit FRUTIL
and resume operations. If this happens, return to step 5.