Technical data

2–29
Compaq HSZ80 Array Controller ACS Version 8.3 Maintenance and Service Guide
6. Enter Y(es) and press return. FRUTIL displays the following:
Quiescing all device ports. Please wait...
Device Port 1 quiesced.
Device Port 2 quiesced.
Device Port 3 quiesced.
Device Port 4 quiesced.
Device Port 5 quiesced.
Device Port 6 quiesced.
All device ports quiesced.
.
.
.
Insert the controller module, WITH its program card, in slot A [
or B
]
within x minutes, xx seconds.
NOTE: A countdown timer allows a total of two minutes to install the controller. If
you exceed two minutes, “this controller” will exit FRUTIL and resume operations.
If this happens, return to step 2.
CAUTION: ESD can easily damage a controller. Wear a snug-fitting,
grounded ESD wrist strap.
Make sure you align the controller in the appropriate guide rails. If you
do not align the controller correctly, damage to the backplane can occur.
7. Ensure that the program card is in the replacement controller and insert the new
controller into its slot. Engage its retaining levers. When fully seated, the newly
installed controller will boot.
FRUTIL displays the following:
If the other controller did not restart, follow these steps:
1. Press and hold the other controller’s reset button.
2. Insert the other controller’s program card.
3. Release the reset button.
Press return to continue.